The use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation
نویسندگان
چکیده
BACKGROUND Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condensers in place of the usual expiratory ventilator circuit and whether PFC liquid could be recovered when using the chilled condensers at the ventilator exhaust outlet. METHODS Using a model lung, perfluorocarbon vapour loss during humidified partial liquid ventilation of a 3.5 kg infant was approximated. For each test 30 mL of FC-77 was infused into the model lung. Condensers were placed in the expiratory limb of the ventilator circuit and the amounts of PFC (FC-77) and water recovered were measured five times. This was repeated with the condensers placed at the ventilator exhaust outlet. RESULTS When the condensers were used as the expiratory limb, the mean (+/- SD) volume of FC77 recovered was 16.4 mL (+/- 0.18 mL). When the condensers were connected to the ventilator exhaust outlet the mean (+/- SD) volume of FC-77 recovered was 7.6 mL (+/- 1.14 mL). The volume of FC-77 recovered was significantly higher when the condenser was used as an expiratory limb. CONCLUSION Using two series connected condensers in the ventilator expiratory line 55% of PFC liquid (FC-77) can be recovered during partial liquid ventilation without altering the function of the of the ventilator circuit. This volume of PFC recovered was just over twice that recovered with the condensers connected to the ventilator exhaust outlet.
منابع مشابه
An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
BACKGROUND The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases contai...
متن کاملSubretinal Perfluorocarbon Liquid (PFCL) after Vitrectomy; A Case Report And Review of Literature
Purpose: To report a case of retained subretinal perfluorocarbon liquid (PFCL) after vitrectomy and to discuss the diagnosis and management of subretinal PFCL based on literature review. Case Report: A 57-year-old female patient underwent 3-port 23-gauge vitrectomy for advanced proliferative diabetic retinopathy and combined tractional and rhegmatogenous retinal detachment. During the surgery, ...
متن کاملPartial liquid ventilation: effects of liquid volume and ventilatory settings on perfluorocarbon evaporation.
During partial liquid ventilation perfluorocarbons are eliminated mainly by evaporation via the airways. The effects of intrapulmonary perfluorocarbon volume, respiratory rate, tidal volume, as well as the level of end-expiratory pressure on perfluorocarbon elimination from isolated lungs, were studied. Nonperfused rabbit lungs underwent partial liquid ventilation (2-15 mL x kg(-1) perfluorocar...
متن کاملChanges in pulmonary blood flow during gaseous and partial liquid ventilation in experimental acute lung injury.
BACKGROUND It has been proposed that partial liquid ventilation (PLV) causes a compression of the pulmonary vasculature by the dense perfluorocarbons and a subsequent redistribution of pulmonary blood flow from dorsal to better-ventilated middle and ventral lung regions, thereby improving arterial oxygenation in situations of acute lung injury. METHODS After induction of acute lung injury by ...
متن کاملCommentary Does perfluorocarbon deoxygenate during partial liquid ventilation?
Perfluorocarbons accumulate in the dependent regions of the lungs, which may result in regional hypoxia if ventilation with oxygen is insufficient to oxygenate the dependent perfluorocarbon-filled alveoli. In this issue of Critical Care, Max et al present data that demonstrate a decrease in arterial oxygen tension (PaO2) at 30 min compared to that observed at 5 min after administration of FC 32...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioMedical Engineering OnLine
دوره 6 شماره
صفحات -
تاریخ انتشار 2007