Determination of trace amounts of off-flavor compounds in drinking water by stir bar sorptive extraction and thermal desorption GC-MS.

نویسندگان

  • N Ochiai
  • K Sasamoto
  • M Takino
  • S Yamashita
  • S Daishima
  • A Heiden
  • A Hoffman
چکیده

A method for the determination of trace amounts of off-flavor compounds including 2-methylisoborneol, geosmin and 2,4,6-trichloroanisole in drinking water was developed using the stir bar sorptive extraction technique followed by thermal desorption-GC-MS analysis. The extraction conditions such as extraction mode, salt addition, extraction temperature, sample volume and extraction time were examined. Water samples (20, 40 and 60 ml) were extracted for 60-240 min at room temperature (25 degrees C) using stir bars with a length of 10 mm and coated with a 500 microm layer of polydimethylsiloxane. The extract was analyzed by thermal desorption-GC-MS in the selected ion monitoring mode. The method showed good linearity over the concentration range from 0.1 or 0.2 or 0.5 to 100 ng l(-1) for all the target analytes, and the correlation coefficients were greater than 0.9987. The detection limits ranged from 0.022 to 0.16 ng l(-1). The recoveries (89-109%) and precision (RSD: 0.80-3.7%) of the method were examined by analyzing raw water and tap water samples fortified at the 1 ng l(-1) level. The method was successfully applied to low-level samples (raw water and tap water).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Residue Method for Determination of 85 Pesticides in Vegetables, Fruits and Green Tea by Stir Bar Sorptive Extraction and Thermal Desorption GC-MS

A multi-residue method to determine fi ve groups of 85 pesticides chlorinated, carbamate, phosphorous, pyrethroid and others in vegetables, fruits and green tea has been developed using stir bar sorptive extraction (SBSE) coupled to thermal desorption and retention time locked (RTL) GC-MS. Pre-extraction with methanol and dilution with water prior to SBSE (60 min) were performed. Dilution of me...

متن کامل

Multi-Residue Method for the Determination of Five Groups of Pesticides in Non-Fatty Food Samples by Dual Stir Bar Sorptive Extraction (Dual SBSE) and Thermal Desorption GC-MS

A multi-residue method for determination of fi ve groups of 85 pesticides organochlorine, carbamate, organophosphorous, pyrethroid and others in non-fatty food, e.g. vegetables, fruits and green tea is described. The method is based on stir bar sorptive extraction (SBSE) coupled to thermal desorption (TD) and retention time locked (RTL) GC-MS

متن کامل

A Novel Extraction Procedure for Stir Bar Sorptive Extraction (SBSE): Sequential SBSE for Uniform Enrichment of Organic Pollutants in Water Samples

A novel stir bar sorptive extraction (SBSE) procedure termed sequential SBSE was developed. Compared to conventional SBSE, sequential SBSE provides more uniform enrichment over the entire polarity/volatility range for organic pollutants at ultra-trace levels in water. Sequential SBSE consists of a SBSE performed sequentially on a 5-mL sample fi rst without modifi er using one stir bar, then on ...

متن کامل

Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction

In this study, a method was developed for quantitative determination of seven phenolic compounds in scotch whisky. Two different whisky brands were analyzed by Stir Bar Sorptive Extraction (SBSE), based on novel EG-Silicone Twisters, combined with thermal desorptiongas chromatography-mass spectrometry (TD-GC-MS). Direct Large Volume Injection (LVI) -GC-MS was used as reference method. Optimized...

متن کامل

Analyze Pesticides in Water with Stir Bar Sorptive Extraction and Thermal Separation

Multiple pesticides in water samples were successfully analyzed using an Agilent 5975T LTM GC/MSD equipped with an Agilent J&W DB-5ms Ultra Inert low thermal mass column module, with stir bar sorptive extraction and an Agilent Thermal Separation Probe for sample preparation. The method was simple, rapid, effective, and showed good linearity (R2 >0.9914) and high sensitivity for most of the targ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 126 10  شماره 

صفحات  -

تاریخ انتشار 2001