Whole-heart cine MRI using real-time respiratory self-gating.

نویسندگان

  • Sergio Uribe
  • Vivek Muthurangu
  • Redha Boubertakh
  • Tobias Schaeffter
  • Reza Razavi
  • Derek L G Hill
  • Michael S Hansen
چکیده

Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods, even those that use undersampling techniques, involve breath-holding for periods that are too long for many patients. Free-breathing respiratory gating sequences represent a possible solution for realizing 3D cine imaging. A real-time respiratory self-gating technique for whole-heart cine MRI is presented. The technique enables assessment of cardiac anatomy and function with minimum planning or patient cooperation. Nonangulated isotropic 3D data were acquired from five healthy volunteers and then reformatted into 2D clinical views. The respiratory self-gating technique is shown to improve image quality in free-breathing scanning. In addition, ventricular volumetric data obtained using the 3D approach were comparable to those acquired with the conventional multislice 2D approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary investigation of respiratory self-gating for free-breathing segmented cine MRI.

Segmented cine MRI generally requires breath-holding, which can be problematic for many patients. Navigator echo techniques, particularly successful for free-breathing coronary MRA, are incompatible with the acquisition strategies and SSFP pulse sequences commonly used for cine MRI. The purpose of this work is to introduce a new self-gating technique deriving respiratory gating information dire...

متن کامل

Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system.

OBJECTIVES The purpose of this study was to validate cardiac measurements derived from real-time cardiac magnetic resonance imaging (MRI) as compared with well-validated conventional cine MRI. BACKGROUND Although cardiac MRI provides accurate assessment of left ventricular (LV) volume and mass, most techniques have been relatively slow and required electrocardiogram (ECG) gating over many hea...

متن کامل

Three-dimensional Whole-Heart Cine MRI using Prospective Self-Gating for Compensation of Cardiac and Respiratory Motion

Introduction: Two-dimensional (2D) breath-hold and ECG-triggered cine MRI is frequently used to assess cardiac function. However this technique requires cooperation from the patient, and the MR acquisition has to be synchronized with the cardiac cycle using ECG. To control respiratory motion, the subject has to perform breath-holds or the position of the diaphragm has to be tracked using a resp...

متن کامل

Feasibility Study: 2-D Self-Navigation using Compressed Sensing Reconstruction for Respiratory Gating in Free-breathing 3-D CINE Imaging

Synopsis We investigate the feasibility of using 2-D self-navigation for respiratory gating for free-breathing whole-heart 3-D CINE imaging, where respirationinduced cardiac motion may be more easily detected than in commonly used 1-D self-navigation methods. We compare self-navigation images, derived gating signals and resulting 3-D CINE images of the 1-D and 2-D methods and nd that respirator...

متن کامل

The accuracy and effectiveness of self-gating signals in free-breathing 3D cardiac cine MRI

Background Conventional cardiac cine magnetic resonance imaging (MRI) is typically based on the segmented data acquired by breath-hold 2D balanced steady-state free procession (SSFP) pulse sequence [1]. However, the slice misregistration caused by the variation of breath holding positions could compromise the effectiveness of 2D SSFP, and breath-hold makes it difficult for pediatric patients or...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2007