Rating of Hearing Protector Performance for Impulse Noise

نویسندگان

  • Daniel L. Johnson
  • James H. Patterson
چکیده

Concern has often been expressed that the performance of hearing protectors in steady noise may not apply to their performance in impulse noise. Our current.studies, as well as other studies, support the fact that there is a large difference in performance. In all cases, the performance of a protector is much better for impulse noise than for continuous noise. For example, we are obtaining at least 20 dB of protection for hearing protectors with a Noise Reduction Rating (NRR) of essentially zero. We believe that it is not the NRR procedure at fault: but the fact that, for impulse noise, A-weighting does not discriminate enough against low-frequency energy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impulse Noise Attenuation: Hearing Protection and Communication in a Military Environment

Military training creates unique noise hazards including high impulse noise content. The need for hearing protection needs to be considered alongside the need for effective voice communication. This requires a hearing protector with high impulse protection that minimally impedes low intensity voice communication. These level dependant devices are called non-linear hearing protectors. A range of...

متن کامل

Effects of peak pressure and energy of impulses.

Peak pressure has been one of the key parameters of impulse noise used to assess the hazard to hearing. It is used in most international noise exposure limits. France uses an A-weighted energy limit. There is a rough correspondence between peak pressure and the hazard to hearing for a given type of impulse noise. However, when the effects of different types of impulses are compared, this corres...

متن کامل

بررسی وضعیت و عوامل موثر در حفاظت شنوایی کارگران صنایع بزرگ شهر همدان در سال 81-1380

Noise induced hearing loss in adults is the most cause of sensory neural hearing loss after the presbycusis and industry workers severity affect by degenerative results of that.           Three large works of Hamadan city which had more than 200 Workers were selected in this demonstrative quest . The mean of sound pressure leve...

متن کامل

Measurement of Insert-type Hearing Protector Attenuation on the End-user: A Practical Alternative to Relying on the NRR Introduction Hearing protectors are labeled with a Noise Reduction Rating

Hearing protectors are labeled with a Noise Reduction Rating (NRR) that is derived from laboratory measurements of the attenuation provided to trained and motivated human subjects in a ‘sterile’ environment. As intended, these measurements represent a best-fit condition. The literature indicates that the average attenuation provided to end-users of hearing protectors is often only a fraction of...

متن کامل

Improved Adaptive Median Filter Algorithm for Removing Impulse Noise from Grayscale Images

Digital image is often degraded by many kinds of noise during the process of acquisition and transmission. To make subsequent processing more convenient, it is necessary to decrease the effect of noise. There are many kinds of noises in image, which mainly include salt and pepper noise and Gaussian noise. This paper focuses on median filters to remove the salt and pepper noise. After summarizin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000