Quality assessment of CoaguChek point-of-care prothrombin time monitors: comparison of the European community-approved procedure and conventional external quality assessment.
نویسندگان
چکیده
BACKGROUND There is a need for dependable quality assessment (QA) of the widely used CoaguChek point-of-care testing prothrombin time monitor. By use of the prescribed set of 5 CoaguChek certified international normalized ratio (INR) QA plasmas, we compared the reliability of the immediate QA of individual monitors described in the European Community-recommended Technology Implementation Plan with conventional external QA analysis. METHODS Experienced staff tested CoaguChek point-of-care monitors in routine use for controlling oral anticoagulant dosage at 9 Netherlands Thrombosis Service Centres. Testing was performed with both the certified CoaguChek INR for a set of 5 QA individual plasmas from the Eur Con Action on Anticoag (ECAA) and conventional external QA analysis. RESULTS Patients brought 523 CoaguChek monitors to our service centers for assessment. The proportion with unsatisfactory performance indicated by a 15% deviation from the ECAA set was compared with 15% deviation from overall median INR of all CoaguChek monitors in the survey, as in conventional QA analysis. The results were similar (20.3% and 18.5%, respectively). Interlot differences of CoaguChek test strips were detected, but the incidence of unsatisfactory performance was similar with both analyses, from 6.5% to 37.5% with the certified INR method and from 5.9% to 33.3% with the overall median analysis. CONCLUSIONS The results validate the use of the European Action on Anticoagulation rapid single-instrument QA-specific procedure for CoaguChek users compared with the nonspecific conventional QA analysis that relies on deviation from the overall median INR.
منابع مشابه
CoaguChek point-of-care testing prothrombin time monitors.
A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by e...
متن کاملA National Field Study of Quality Assessment of CoaguChek Point-of-Care Testing Prothrombin Time Monitors
A system for quality assessment (QA) of the CoaguChek (Roche Diagnostics, Mannheim, Germany) point-of-care testing prothrombin time monitor has been developed by the European Concerted Action on Anticoagulation. Hitherto there has not been an adequate rapid method for CoaguChek QA. Sets of 5 certified international normalized ratio (INR) plasma samples were tested on 539 CoaguChek monitors by e...
متن کاملExternal quality assessment (EQA) for CoaguChek monitors.
Anticoagulant control facilities are being overwhelmed by requests for monitoring and large numbers of patients are not therefore receiving treatment. Procedures designed for point-of-care testing have therefore been developed, the most popular being the CoaguChek. The need for external quality assessment (EQA) of monitors used by patients in self-management has been stressed in a European Comm...
متن کاملTherapeutic concordance of two portable monitors and two routine automatic oral anticoagulant monitoring systems using as reference the manual prothrombin time technique.
Two models of capillary blood prothrombin time (PT) monitoring systems were evaluated for analytical performance and then compared with two routine PT systems using the reference manual technique and a high-sensitivity thromboplastin. Two sets of 60 and 80 plasmas were analyzed from anticoagulated patients stabilized over 3 months in an INR range 2-3.5 for therapy. Capillary PT determination wa...
متن کاملEuropean concerted action on anticoagulation. Quality assessment of the CoaguChek Mini and TAS PT-NC point-of-care whole-blood prothrombin time monitors.
BACKGROUND International Normalized Ratios (INRs) for prothrombin time obtained with the CoaguChek Mini and TAS (RapidPointCoag) PT-NC systems are markedly different and also differ from the "true" INR. There is therefore a need for local quality assessment (QA) of the two systems. METHODS A set of 60 lyophilized artificially depleted and 60 lyophilized coumarin plasmas were tested at 10 cent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 52 10 شماره
صفحات -
تاریخ انتشار 2006