Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS)
نویسندگان
چکیده
Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from further research on the separation properties of empty fused silica tubing. The efficiency of this chromatographic system has been examined. The usefulness of such conditions has been studied for simulated distillation, i.e. to determine the boiling-point distribution of complex mixtures, mainly petroleum fractions and products, on the basis of their retention relative to reference substances. The results obtained by use of empty-column gas chromatography (EC-GC) and by use of classical simulated distillation columns have been compared for solutes of different polarity. Studies revealed boiling points determined by EC-GC were more accurate than those obtained by the standard method of simulated distillation.
منابع مشابه
Fast Simulated Distillation Based on Agilent 6890N GC
A rapid simulated distillation method is described for analysis of petroleum fractions boiling within the range of ASTM D2887 [1]. The method employs an Agilent 6890N gas chromatograph (GC) equipped with a split/splitless inlet, flame ionization detector (FID), oven insert, and 3-meter 180-μm id capillary column. A SIMDIS software package is partially integrated into the GC ChemStation for data...
متن کاملCharacterisation of middle-distillates by comprehensive two-dimensional gas chromatography (GC x GC): A powerful alternative for performing various standard analysis of middle-distillates.
The detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- ...
متن کاملFast Hydrocarbon and Sulfur Simulated Distillation Using the Agilent Low Thermal Mass (LTM) System on the 7890A GC and 355 Sulfur Chemiluminescence Detector
A fast multielement simulated distillation method (SimDis) based on Low Thermal Mass (LTM) column technology is described. The LTM system technology using resistive heating allows rapid temperature programming with extremely fast column cooldown. Significantly shortened analytical cycle times as compared to conventional air bath GC ovens are achieved. The method combines hydrocarbon SimDis with...
متن کاملSimulated Distillation System for ASTM D2887, Based on the Agilent 6890N GC
An Agilent Simulated Distillation (SIMDIS) system is described for quality control and monitoring of refinery processes. The system uses an Agilent 6890N gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) inlet designed specifically for high temperature analysis. A simulated distillation software program that couples with the Agilent GC ChemStation provides an easy-...
متن کاملHigh-Temperature Simulated Distillation System Based on the 6890N GC
An Agilent Simulated Distillation (SimDis) system is described for characterizing petroleum fractions for quality control and monitoring of refinery feedstocks and products. The system uses a 6890N gas chromatograph (GC) equipped with a high temperature programmable temperature vaporizer (HT PTV) inlet designed specifically for simulated distillation analysis. A SimDis software program that cou...
متن کامل