UK Renal Registry 13th Annual Report (December 2010): Chapter 8: adequacy of haemodialysis in UK adult patients in 2009: national and centre-specific analyses.

نویسندگان

  • Anna Casula
  • Lynsey Webb
  • Terry Feest
چکیده

BACKGROUND Outcome in patients treated with haemodialysis (HD) is influenced by the delivered dose of dialysis. The UK Renal Association (RA) publishes Clinical Practice Guidelines which include recommendations for dialysis dose. The urea reduction ratio (URR) is a widely used measure of dialysis dose. AIM To determine the extent to which patients received the recommended dose of HD in the UK. METHODS All seventy-two UK renal centres submitted data to the UK Renal Registry (UKRR). Two groups of patients were included in the analyses: the prevalent patient population on 31st December 2009 and the incident patient population for 2009. Centres returning data on <50% of their patient population were excluded from centre-specific comparisons. RESULTS Data regarding URR were available from 63 renal centres in the UK. Fifty-one centres provided URR data on more than 90% of prevalent patients. The proportion of patients in the UK who met the UK Clinical Practice Guideline for URR (>65%) increased from 56% in 1998 to 85.5% in 2009. There was considerable variation between centres, with 19 centres attaining the RA clinical practice guideline in >90% of patients and 5 centres attaining the guideline in <70% of patients. The delivered HD dose (URR) was lower in patients who had just commenced dialysis treatment compared to patients who had survived longer on HD. CONCLUSIONS The delivered dose of HD for patients with established renal failure has increased over the last decade. Whilst the majority of UK patients achieved the target URR there was considerable variation between centres in the percentage of patients achieving the guideline.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UK Renal Registry 11th Annual Report (December 2008): Chapter 8 Adequacy of haemodialysis in UK renal centres in 2007: national and centre-specific analyses.

BACKGROUND Outcome in patients treated with haemodialysis (HD) is influenced by the delivered dose of dialysis. The UK Renal Association (RA) publishes Clinical Practice Guidelines which include recommendations for dialysis dose. The urea reduction ratio (URR) is a widely used measure of dialysis dose. AIM To determine the extent to which patients received the recommended dose of HD in the UK...

متن کامل

UK Renal Registry 12th Annual Report (December 2009): Chapter 8 Adequacy of Haemodialysis in UK Renal Centres in 2008: national and centre-specific analyses

Background: Outcome in patients treated with haemodialysis (HD) is influenced by the delivered dose of dialysis. The UK Renal Association (RA) publishes Clinical Practice Guidelines which include recommendations for dialysis dose. The urea reduction ratio (URR) is a widely used measure of dialysis dose. Aim: To determine the extent to which patients received the recommended dose of HD in the UK...

متن کامل

UK Renal Registry 11th Annual Report (December 2008): Chapter 15 The UK Renal Registry, UKRR database, validation and methodology.

The UK Renal Registry receives encrypted data extracts quarterly from each centre providing Renal Replacement Therapy (RRT) in England, Wales and Northern Ireland. Summary data is received from the Scottish Renal Registry to allow national statistics to be compiled. Data from patients receiving haemodialysis in satellite units or at home are reported through the main renal centre. Data from pat...

متن کامل

UK Renal Registry 19th Annual Report: Chapter 6 Adequacy of Haemodialysis in UK Adult Patients in 2015: National and Centre-specific Analyses.

BACKGROUND Outcomes in patients treated with haemodialysis(HD) are potentially influenced by the delivered dose of dialysis. The UK Renal Association publishes clinical practice guidelines recommendations for dialysis dose. The urea reduction ratio (URR) is a widely used measure of dialysis dose and has been historically the measure of adequacy reported by the UKRR. AIM To determine the exten...

متن کامل

UK Renal Registry 15th annual report: Appendix E methodology for estimating catchment populations of renal centres in England for dialysis patients.

Providing accurate centre-level incidence and prevalence rates for patients receiving renal replacement therapy (RRT) in the UK was limited until the 13th Annual Report by the difficulty in estimating the catchment population from which the RRT population was derived. One reason for this was that the geographical boundaries separating renal centres are relatively arbitrary and dependent upon a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephron. Clinical practice

دوره 119 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2011