Direct detection of adenosine in undiluted serum using a luminescent aptamer sensor attached to a terbium complex.
نویسندگان
چکیده
Aptamers, single-stranded nucleic acids that can selectively bind to various target molecules, have been widely used for constructing biosensors. A major challenge in this field, however, is direct sensing of analytes in complex biological media such as undiluted serum. While progress has been made in developing an inhomogeneous assay by using a preseparation step to wash away the interferences within serum, a facile strategy for direct detection of targets in homogeneous unprocessed serum is highly desired. We herein report a turn-on luminescent aptamer biosensor for the direct detection of adenosine in undiluted and unprocessed serum, by taking advantage of a terbium chelate complex with long luminescence lifetime to achieve time-resolved detection. The sensor exhibits a detection limit of 60 μM adenosine while marinating excellent selectivity that is comparable to those in buffer. The approach demonstrated here can be applied for direct detection and quantification of a broad range of analytes in biological media by using other aptamers.
منابع مشابه
Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor.
The development of a biosensor system capable of continuous, real-time measurement of small-molecule analytes directly in complex, unprocessed aqueous samples has been a significant challenge, and successful implementation has been achieved for only a limited number of targets. Toward a general solution to this problem, we report here the Microfluidic Electrochemical Aptamer-based Sensor (MECAS...
متن کاملTerbium(III) complex as a luminescent sensor for human serum albumin in aqueous solution.
A terbium(III) complex gives off strong luminescence upon reacting with human serum albumin in aqueous solution, which can be used to detect the presence and structural modifications of this protein.
متن کاملDetermination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method
A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...
متن کاملStudy of Aptamer-Attached Juglone in Different pH Ranges and Ionic Concentrations of Buffers
Electrochemical aptamer-based sensors attract a lot of interest as useful methods because of their low cost, accuracy, sensitivity, and simplicity. An electro-active redox molecule comprises the main part of the electrochemical-based sensors. Ferrocene is one of the most popular redox molecule used in biosensor fabrication. But, instability of ferrocenium ion in strong nucleophilic reagents...
متن کاملDevelopment and Validation of a Terbium-Sensitized Luminescence Analytical Method for Deferiprone
A sensitive fluorometric method for the determination of deferiprone (DFP) based on the formation of a luminescent complex with Tb3+ ions in aqueous solutions is reported. The maximum excitation and emission wavelengths were 295 and 545 nm, respectively. The effects of various factors on the luminescence intensity of the system were investigated and optimized, then under the optimum conditions,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 84 18 شماره
صفحات -
تاریخ انتشار 2012