The PROSTALAC functional spacer in two-stage revision for infected knee replacements. Prosthesis of antibiotic-loaded acrylic cement.
نویسندگان
چکیده
The PROSTALAC functional spacer is made of antibiotic-loaded acrylic cement but has a small metal-on-polythene articular surface. We have used it as an interim spacer in two-stage exchange arthroplasty for infected total knee replacement. PROSTALAC allows continuous rehabilitation between stages as it maintains good alignment and stability of the knee and a reasonable range of movement. It also helps to maintain the soft-tissue planes, which facilitates the second-stage procedure. We reviewed 45 consecutive patients, treated over a period of nine years. The mean follow-up was for 48 months (20 to 112). At final review, there was no evidence of infection in 41 patients (91%); only one had a recurrent infection with the same organism. There was improvement in the Hospital for Special Surgery knee score between stages and at final review. The range of movement was maintained between stages. Complications were primarily related to the extensor mechanism and stability of the knee between stages. Both of these problems decreased with refinement of the design of the implant. The rate of cure of the infection in our patients was similar to that using other methods. Movement of the knee does not appear to hinder control of infection.
منابع مشابه
Technical Tip for Prosthesis of Antibiotic-Loaded Acrylic Cement (PROSTALAC) Use for Infection after Shoulder Arthroplasty
©2015 by The Orthopaedic Journal at Harvard Medical School BACKGROUND Shoulder arthroplasty procedures have generally excellent clinical outcomes, but infection following shoulder arthroplasty continues to be a difficult problem both diagnostically and therapeutically. Two-stage reimplantation with use of a temporary Prosthesis of Antibiotic-Loaded Acrylic Cement (PROSTALAC) (DePuy, Warsaw, Ind...
متن کاملTwo-stage exchange of infected knee arthroplasty with an prosthesis-like interim cement spacer.
Two-stage revision in infected knee arthroplasty is standard practice. One problem during the interim period is soft tissue fibrosis. Attempts have been made to preserve leg length and ligament length by introducing spacers, usually made out of antibiotic-loaded bone cement. We present a new interim prosthesis, which is made intra-operatively out of polymethylmethacrylate (PMMA). Antibiotic-loa...
متن کاملSonication of antibiotic-loaded cement spacers in a two-stage revision protocol for infected joint arthroplasty
BACKGROUND Culturing of the sonication fluid of removed implants has proven to be more sensitive than conventional periprosthetic tissue culture for the microbiological diagnosis of prosthetic joint infection. Since bacteria surviving on antibiotic-loaded cement spacers used in a two-stage exchange protocol for infected arthroplasties may cause the persistence of infection, in this study we ask...
متن کاملTwo-Stage Revision Using a Modified Articulating Spacer in Infected Total Knee Arthroplasty
PURPOSE To evaluate clinical results of two-stage revision using a modified articulating spacer for treatment of infected total knee arthroplasty (TKA). MATERIALS AND METHODS We retrospectively reviewed 20 cases treated by two-stage revision arthroplasty using a modified articulating spacer under the diagnosis of infected TKA from January 2006 to December 2011. The mean follow-up period was 2...
متن کاملTwo-stage revision of infected total knee replacements using articulating cement spacers and short-term antibiotic therapy.
We present a series of 48 patients with infected total knee replacements managed by the use of articulating cement spacers and short-term parenteral antibiotic therapy in the postoperative period. All patients had microbiological and/or histological confirmation of infection at the first stage of their revision. They all underwent re-implantation and had a mean follow-up of 48.5 months (26 to 8...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 82 6 شماره
صفحات -
تاریخ انتشار 2000