Effect of quality metric monitoring and colonoscopy performance

نویسندگان

  • Anthony Razzak
  • Dineen Smith
  • Maliha Zahid
  • Georgios Papachristou
  • Asif Khalid
چکیده

Background and aims: Adenoma detection rate (ADR) and cecal withdrawal time (CWT) have been identified as measures of colonoscopy quality. This study evaluates the impact of monitoring these measures on provider performance. Methods: Six blinded gastroenterologists practicing at a Veterans Affairs Medical Center were prospectively monitored over 9 months. Data for screening, adenoma surveillance, and fecal occult blood test positive (FOBT +) indicated colonoscopies were obtained, including exam preparation quality, cecal intubation rate, CWT, ADR, adenomas per colonoscopy (APC), and adverse events. Metrics were continuously monitored after a period of informed CWT monitoring and informed CWT + ADR monitoring. The primary outcome was impact on ADR and APC. Results: A total of 1671 colonoscopies were performed during the study period with 540 before informed monitoring, 528 during informed CWT monitoring, and 603 during informed CWT + ADR monitoring. No statistically significant impact on ADR was noted across each study phase. Multivariate regression revealed a trend towards fewer adenomas removed during the CWT monitoring phase (OR = 0.79; 95 %CI 0.62 - 1.02, P = 0.065) and a trend towards more adenomas removed during the CWT + ADR monitoring phase when compared to baseline (OR = 1.26; 95 %CI 0.99 - 1.61, P = 0.062). Indication for examination and provider were significant predictors for higher APC. Provider-specific data demonstrated a direct relationship between high ADR performers and increased CWT. Conclusions: Monitoring quality metrics did not significantly alter colonoscopy performance across a small heterogeneous group of providers. Non-significant trends towards higher APC were noted with CWT + ADR monitoring. Providers with a longer CWT had a higher ADR. Further studies are needed to determine the impact of monitoring on colonoscopy performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase II monitoring of multivariate simple linear profiles with estimated parameters

In some applications of statistical process monitoring, a quality characteristic can be characterized by linear regression relationships between several response variables and one explanatory variable, which is referred to as a “multivariate simple linear profile.” It is usually assumed that the process parameters are known in Phase II. However, in most applications, this assumption is viola...

متن کامل

Comparison of two different methods of colon cleansing for afternoon-colonoscopy

Background: The appropriate colon cleansing is a major determinant of quality of colonoscopy. The aim of this study was to compare the efficacy and tolerability of the morning (AM) PEG (polyethylene glycol) solution to previous-evening (PM) PEG solution for the afternoon colonoscopy. Methods: This comparative study compared the AM to PM prep for afternoon outpatient colonoscopy. The subjects r...

متن کامل

EFFECT OF LOCATION OF EXPLANATORY VARIABLE ON MONITORING POLYNOMIAL QUALITY PROFILES

The quality is typically modeled as the univariate or multivariate distribution of quality characteristic/s. In recent applications of statistical process control, quality profiles in which the relationship between a response and explanatory variable/s is captured and monitored are increasingly used to model the quality. Several techniques have been developed to enhance the speed of detecting c...

متن کامل

Investigating Effect of Autocorrelation on Monitoring Multivariate Linear Profiles

Abstract Profile monitoring in statistical quality control has attracted attention of many researchers recently. A profile is a function between response variables and one or more independent variables. There have been only a limited number of researches on monitoring multivariate profiles. Indeed, monitoring correlated multivariate profiles is a new subject in the fileld of statistical proces...

متن کامل

Optimized Sedation Improves Colonoscopy Quality Long-Term

Background. Quality monitoring and improvement is prerequisite for efficient colonoscopy. Aim. To assess the effects of increased sedation administration on colonoscopy performance. Materials and Methods. During Era 1 we prospectively measured four colonoscopy quality indicators: sedation administration, colonoscopy completion rate, adenoma detection rate, and early complications rate in three ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016