Vibratory adaptation of cutaneous mechanoreceptive afferents.
نویسندگان
چکیده
The objective of this study was to investigate the effects of extended suprathreshold vibratory stimulation on the sensitivity of slowly adapting type 1 (SA1), rapidly adapting (RA), and Pacinian (PC) afferents. To that end, an algorithm was developed to track afferent absolute (I0) and entrainment (I1) thresholds as they change over time. We recorded afferent responses to periliminal vibratory test stimuli, which were interleaved with intense vibratory conditioning stimuli during the adaptation period of each experimental run. From these measurements, the algorithm allowed us to infer changes in the afferents' sensitivity. We investigated the stimulus parameters that affect adaptation by assessing the degree to which adaptation depends on the amplitude and frequency of the adapting stimulus. For all three afferent types, I0 and I1 increased with increasing adaptation frequency and amplitude. The degree of adaptation seems to be independent of the firing rate evoked in the afferent by the conditioning stimulus. In the analysis, we distinguished between additive adaptation (in which I0 and I1 shift equally) and multiplicative effects (in which the ratio I1/I0 remains constant). RA threshold shifts are almost perfectly additive. SA1 threshold shifts are close to additive and far from multiplicative (I1 threshold shifts are twice the I0 shifts). PC shifts are more difficult to classify. We used an integrate-and-fire model to study the possible neural mechanisms. A change in transducer gain predicts a multiplicative change in I0 and I1 and is thus ruled out as a mechanism underlying SA1 and RA adaptation. A change in the resting action potential threshold predicts equal, additive change in I0 and I1 and thus accounts well for RA adaptation. A change in the degree of refractoriness during the relative refractory period predicts an additional change in I1 such as that observed for SA1 fibers. We infer that adaptation is caused by an increase in spiking thresholds produced by ion flow through transducer channels in the receptor membrane. In a companion paper, we describe the time-course of vibratory adaptation and recovery for SA1, RA, and PC fibers.
منابع مشابه
Time-course of vibratory adaptation and recovery in cutaneous mechanoreceptive afferents.
Extended suprathreshold vibratory stimulation applied to the skin results in a desensitization of cutaneous mechanoreceptive afferents. In a companion paper, we describe the dependence of the threshold shift on the parameters of the adapting stimulus and discuss neural mechanisms underlying afferent adaptation. Here we describe the time-course of afferent adaptation and recovery. We found that ...
متن کاملComparing the effects of isoflurane and pentobarbital on the responses of cutaneous mechanoreceptive afferents
BACKGROUND While pentobarbital has been used extensively in neurophysiological experiments investigating activity in peripheral nerves, it has fallen out of favor as an anesthetic because of safety concerns and is often replaced with isoflurane. However, the effects of isoflurane on the excitability of mechanoreceptive afferents have yet to be conclusively elucidated. METHODS To fill this gap...
متن کاملParadoxes in tactile adaptation. Focus on "vibratory adaptation in cutaneous mechanoreceptive afferents" and "time-course of vibratory adaptation and recovery in cutaneous mechanoreceptive afferents".
Whenever we manipulate an object, or explore it using touch, sensory adaptation occurs in some form and this is likely to have an impact on perception and probably on sensorimotor control. Adaptation may be occurring at the level of the skin and receptor, at a central level, or some combination of the two. Although it has been known for many years that adaptation occurs (Berglund and Berglund 1...
متن کاملVibration Exposure of the Glabrous Skin of the Human Hand
Lundström, Ronnie, 1985. Vibration exposure of the glabrous skin of the human hand. Umeå University, Medical Dissertions, New Series, 136. An occupational exposure to hand-arm vibration can cause a complex of neu rological, vascular and musculo-skeletal disturbances, known as the 'vibra tion syndrome'. However, the underlying pathophysiological mechanisms are not at all clear. Early signs of ...
متن کاملSensations evoked by microstimulation of single mechanoreceptive afferents innervating the human face and mouth.
Intraneural microneurography and microstimulation were performed on single afferent axons in the inferior alveolar and lingual nerves innervating the face, teeth, labial, or oral mucosa. Using natural mechanical stimuli, 35 single mechanoreceptive afferents were characterized with respect to unit type [fast adapting type I (FA I), FA hair, slowly adapting type I and II (SA I and SA II), periodo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurophysiology
دوره 94 5 شماره
صفحات -
تاریخ انتشار 2005