To Compare the Microleakage Among Experimental Adhesives Containing Nanoclay Fillers after the Storages of 24 Hours and 6 Months

نویسندگان

  • Seyed Mostafa Mousavinasab
  • Mohammad Atai
  • Bagher Alavi
چکیده

OBJECTIVES To compare the microleakage among experimental adhesives containing nanoclay fillers after the storages of 24 hours and 6 months. MATERIALS AND METHODS Class V cavities were prepared on extracted human molars with the occlusal margins located in enamel and the cervical margins in cementum. Phosphoric acid was applied to the enamel and dentin margins.Subsequently, the cavities were treated using four groups of experimental adhesive systems and restored with a resin composite. Adper Single Bond® was used as control group. After 24- hour and 6- month storages, the samples were subjected to thermocycling shocks and then immersed in silver nitrate as well as developer solution and finally evaluated for leakage. The data were analyzed using SPSS software. RESULTS Based on Kruskal -Wallis test, significant differences were found between groups regarding microleakage. The Mann- Whitney test showed that Leakage was significantly lower in Adper Single Bond® compared to the other groups in dentinal margins after 24 hours and 6 months and in enamel margins after 6 months. The Wilcoxon Signed Ranks test showed that the enamel leakage in experimental adhesives was significantly lower than dentinal leakage after 24 hours as well as enamel leakage in Adper Single Bond and adhesive with 0.5% PMAA-g-nanoclay was significantly lower than dentinal margins after storage period of 6 months. CONCLUSION All the experimental adhesives were effective in reducing enamel leakage after 24 hours, but were not effective in reducing dentinal leakage after 24 hours as well as in enamel and dentinal leakage after a 6-month storage. No improvement was observed in the microleakage in dentin in both short (24 hrs) and long times (6 months). The high microleakage in the adhesives is probably attributed to the high concentration of HEMA in the recipe of the bonding agent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage of Bulk-Fill Composites at Two Different Time Points

Objectives: Microleakage is the main concern in composite restorations. This study aimed to compare the microleakage of two bulk-fill and one conventional composite at two different time points. Methods: Class II cavities were prepared in 60 premolar teeth and divided into six groups of 20. Groups 1 and 4 were incrementally filled with Grandio composite. Groups 2 and 5 were filled with X-tra...

متن کامل

Sodium fluoride addition to a two-step etch-and-rinse adhesive system: effect on dentin microtensile bond strength and durability

Introduction: Studies have suggested that sodium fluoride (NaF) has an inhibitory effect on the activity of endogenous matrix metalloproteinase enzymes. This study assessed the effect of a fluoride-containing adhesive on microtensile bond strength (µTBS) over time. Material & Methods: In this experimental study, 36 extracted  third molars were used to evaluate the µTBS of...

متن کامل

ریزنشت سیستم‌های ادهزیو توتال اچ و سلف اچ در حفرات کلاس V کامپوزیتی

Background and Aims: This ex vivo study was done to evaluate the effect of different adhesive systems on microleakage of class V composite restorations.Materials and Methods: Thirty extracted human third molar teeth were selected and class V cavities were prepared (3×3×1.5 mm) on buccal and lingual surfaces. Then, teeth were divided into 3 groups. Adhesives used in this study were Excite (Ivocl...

متن کامل

Effect of Thermocycling on Microleakage of New Adhesive Systems on Primary Teeth: An In-Vitro Study

Introduction: This study investigated the sealing ability of three different adhesives in primary bovine teeth. Methods: Facial and lingual class V cavities were prepared half in enamel and half in cementum, in 48 bovine primary mandibular incisors and randomly divided into three groups and each group divided to two subgroups. The tested adhesives were XPBond (XP), ClearfilS3 Bond (S3), and Xen...

متن کامل

Microleakage assessment of one- and two-step self-etch adhesive systems with ‎the low shrinkage composites

BACKGROUND AND AIM: Different studies evaluating one-step self-etch (SE) adhesive systems show contradictory findings, so the aim of this study was to compare the microleakage of one-step SE adhesive systems and CLEARFIL SE BOND (that serves as the “gold-standard” SE adhesive) with low shrinkage composites. METHODS: In this in vitro study, Class V cavities with the occlusal margin in enamel and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011