Fast temperature measurement using a 2DRF pulse enables both reduced-FOV imaging and fat suppression

نویسندگان

  • C-S. Mei
  • J. Yuan
  • N. J. McDannold
  • L. P. Panych
چکیده

Fig.4: Temperature changes of a cheese phantom at the hottest voxel during FUS heating experiments. While measurements using GE fast gradient-echo sequence are echo time-dependent (a), the measurements using 2DRF pulse for fat suppression are very similar (b). With excitation pattern of Fig.2d, both fat suppression and 2D excitation were achieved, resulting in improvement in temporal resolution by 2.3 fold as shown in the red line. Fig.1: A 11*1140μs 2DRF pulse for fat suppression and rFOV imaging at 3T Fast temperature measurement using a 2DRF pulse enables both reduced-FOV imaging and fat suppression

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatially variable fat-water separation using short 2DRF pulses for fast imaging

5*560μs pulse (a) left: fat+water, right: water-only (b) left: water-only, right: signal null; (c) left: signal null, right: fat-only (d) left: fat-only, right: fat+water. Fig.2. (a) full FOV fat-water separation at 3T with a 5*1136μs pulse; (b) rFOV separation (RFOV=2) with a 9*1136μs pulse; (c) full FOV separation with a 5*720μs pulse; (d) spatially variable separations with a 5*560μs pulse. ...

متن کامل

3D reduced-FOV MR thermometry with fat suppression using a hybrid method combining a 2DRF pulse, parallel imaging, and UNFOLD

Fig.4: Temperature changes of the hottest voxel in 2D cheese experiments. While the conventional sequence (magenta) underestimated temperatures due to the presence of fat, the present method (green) suppressed fat and reduced imaging time by 8-fold. Green line is the result of temporal average over a sliding window of 8 time frames. Fig.2: Excitation profile in a cheese phantom. The distance be...

متن کامل

Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging.

Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced suscept...

متن کامل

Fast Cardiac Imaging using a Novel Reduced-FOV Excitation and EPI Acquisition

Introduction: Single-shot cardiac imaging was first proposed by the Mansfield group in the 1977 [1]. We present new RF pulses to increase acquisition speed in conjunction with single-shot and 2interleaved circular EPI readouts. Methods: Experiments were performed on a GE Signa EXCITE 3.0T system using a custom real-time imaging system [2]. Two new reduced FOV excitation pulses [3] were used whi...

متن کامل

The Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008