Fatal Basilar Aneurysm Rupture 6 Months Following Pipeline Flow Diversion Treatment
نویسندگان
چکیده
The introduction of flow diverters represents a major paradigm shift in the endovascular treatment of intracranial aneurysms from deconstructive, endosaccular, aneurysm treatment to reconstructive, endoluminal, diseased parent vessel treatment. The theoretical concept of flow diversion (FD) technology relies on the ability offlowdiverters to induce a change in arterial and intra-aneurysmal hemodynamics leading to progressive thrombosis, occlusion, and subsequent healing of the aneurysm.1 However, the time course of the healing process to occur is unclear and is probably influenced by factors such as aneurysm size and morphology, the type of flow diverter used, the resultant flow change, the parent vessel geometry, and the patient’s blood coagulation profile.1,2 Thus, an aneurysm may remain unprotected and prone to rupture for an uncertain period after endovascular FD treatment. Delayed aneurysmal rupture post-FD treatment has been estimated to occur in 1% of all aneurysms treated and in 2% of aneurysms larger than 10 mm.1 Very delayed aneurysm
منابع مشابه
Effect of flow diversion treatment on very small ruptured aneurysms.
BACKGROUND Ruptured aneurysms of < 2 mm are not amenable to endovascular coiling and therefore pose a significant treatment challenge. OBJECTIVE To test recently introduced flow diverters that allow endovascular reconstruction via another method and may represent a new treatment option for such lesions. PATIENTS AND METHODS Three female patients presented with acute subarachnoid hemorrhage....
متن کاملDelayed spontaneous rupture of a posterior inferior cerebellar artery aneurysm following treatment with flow diversion: a clinicopathologic study.
In this report, we present the fatal spontaneous delayed rupture of a previously unruptured large PICA aneurysm following treatment with the PED. Pathology at postmortem examination has supported the theory that intra-aneurysmal thrombus may acutely destabilize the aneurysm wall. Aneurysms with an anatomic arrangement that promote continued flow into the neck may not be optimal candidates for t...
متن کاملIntra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment.
BACKGROUND AND PURPOSE FD technology enables reconstructive repair of otherwise difficult-to-treat intracranial aneurysms. These stentlike devices may induce progressive aneurysm thrombosis without additional implants and may initiate complete reverse vessel remodeling. The associated vascular biologic processes are as yet only partially understood. MATERIALS AND METHODS From 12 different cen...
متن کاملDouble-barrel Y-configuration Stenting for Flow Diversion of a Giant Recurrent Basilar Apex Aneurysm with the Pipeline Flex Embolization Device
Giant basilar apex aneurysms are extremely challenging to successfully manage. The Pipeline Flex embolization device (PFED) is a new generation flow-diverting stent with a modified delivery system which allows resheathing of the stent after partial deployment. We describe a case of double-barrel Y-configuration stenting of a giant, recurrent basilar apex aneurysm using the PFED. A 73-year-old m...
متن کاملPatency of the anterior choroidal artery after flow-diversion treatment of internal carotid artery aneurysms.
BACKGROUND AND PURPOSE Treatment of cerebral aneurysms with flow diverters often mandates placement of the device across the ostia of major branches of the internal carotid artery. We determined the patency rates of the anterior choroidal artery after placement of flow-diversion devices across its ostium. MATERIALS AND METHODS We analyzed a consecutive series of patients in whom a Pipeline Em...
متن کامل