Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry

نویسنده

  • M Hickey
چکیده

Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO2). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO2 in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO2 in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO2 in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1 mm and 2 mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO2) in the splanchnic region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of oxygen saturation derived from cardiac pulsations measured on the adult head using NIR spectroscopy.

Cardiac related pulsatile signals can be detected in different parts of the human body, including the finger, ear lobe and forehead [1] by using near infrared (NIR) monitoring. These pulsatile signals are due to attenuation of light by the increase of arterial blood volume during systole in the cardiac cycle. Pulse oximetry exploits these pulsatile signals to calculate oxygen saturation (SpO2) ...

متن کامل

Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel.

PURPOSE OF REVIEW This article reviews the development of novel reflectance pulse oximetry sensors for the esophagus and bowel, and presents some of the techniques used to analyze the waveforms acquired with such devices. RECENT FINDINGS There has been much research in recent years to expand the utility of pulse oximetry beyond the simple measurement of arterial oxygen saturation from the fin...

متن کامل

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

Evaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals

Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...

متن کامل

Accuracy of fetal pulse oximetry and pitfalls in measurements.

Pulse oximetry is a technique for estimating arterial oxygen saturation continuously and non-invasively. Reflectance pulse oximetry might become useful for monitoring the fetus during labour but it is much more susceptible to all kinds of physiological variations than the well-established transmission pulse oximetry for neonatal or adult monitoring. This review focuses on the accuracy of reflec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016