A 64-year-old man with multiple comorbidities (obesity and metabolic syndrome, dilated cardiomyopathy, type 2 diabetes mellitus, chronic renal insufficiency, obstructive sleep apnea syndrome, and colonic diverticula) underwent anterior resection for distal rectal cancer with protective ileostomy. A few days later, enteral juice was flowing from surgical drains; an urgent endoscopy with fluoroscopy showed the presence of a small (8-mm) anastomotic leak, which was managed conservatively. At 1-month follow-up, endoscopy showed a 75% anastomotic dehiscence with intraluminal migration of a drain (●" Fig.1). The patient’s clinical condition worsened and, after multidisciplinary discussion, an endoscopic transanastomotic fully covered metal stent placement was planned. The ideal stent had to have a large bore, be sufficiently long, and to have an antimigration system. A large-bore over-thewire stent with a double antimigration system appeared to have these features (head diameter 32mm, body diameter 24 mm, length 18cm, BETA stent; Taewoong Medical, Gyeonggi-do, South Korea) (●" Fig.2). As the stent was developed for the treatment of postbariatric surgery leak, specific measures were taken to ensure its antimigration activity and to place the larger stent flare proximally in the colon. On the back table, the stent was released inside a 32-Fr tube; the tube and enclosed stent were then turned round, and the stent was reassembled by inserting the original release system but through the opposite end of the stent (●" Fig.3). With the patient under deep sedation, and using endoscopic and radiologic control, the stent was easily released across the anastomotic dehiscence (●" Fig.4). Enteric flow through the abdominal drain immediately stopped, allowing removal of the drain 1 week later. The stent was removed 3 months later, and endoscopy showed complete anastomotic dehiscence resolution (●" Fig.5). The patient remained asymptomatic during the 8-month followup. Fig.1 Post-surgical anastomosis dehiscence in a 64-year-old man after anterior resection for distal rectal cancer. A migrated surgical drain can be seen. a Before lavage; b after lavage.
منابع مشابه
Minimally invasive management of anastomotic leaks in colorectal surgery
Anastomotic leakage is an unfortunate complication of colorectal surgery. This distressing situation can cause severe morbidity and significantly affects the patient's quality of life. Additional interventions may cause further morbidity and mortality. Parenteral nutrition and temporary diverting ostomy are the standard treatments of anastomotic leaks. However, technological developments in min...
متن کاملSuccessful recanalization of complete anastomotic stricture using colorectal endoscopic ultrasound-guided rendezvous thus allowing stoma reversal: two cases.
Anastomotic stricture frequently occurs with colorectal surgery [1]. Endoscopic dilation or stenting may be used to avoid surgical reintervention [2]. If this fails, endoscopic ultrasound (EUS)-guided stent placement has been proposed [3]. We report two cases of successful EUS-guided colorectal stricture recanalization made possible by two methods of filling the colonwithwater (●" Fig.1;●" Vide...
متن کاملEndoscopic Management of Acute Colorectal Anastomotic Complications With Temporary Stent
Acute postoperative anastomotic complications following colorectal resection include leak and obstruction. Often an operation is necessary to treat these complications. The role of endoluminal procedures to treat these complications has been limited. This article illustrates that such an approach is technically feasible and can be used to treat some colorectal anastomotic complications.
متن کاملCustomized partially covered biodegradable stent for anastomotic leakage after esophagojejunostomy.
stent for anastomotic leakage after esophagojejunostomy A 73-year-old man underwent a total gastrectomy plus splenectomy for a gastric adenocarcinoma (T3N1M0). At the early postoperative stage, the patient presented an esophagojejunostomy leak (>1cm diameter;●" Fig.1a). Medical management and endoscopic treatment were considered first. A customized, partially covered biodegradable stent (●" Fig...
متن کاملIntraoperative air testing of colorectal anastomoses.
INTRODUCTION Intraoperative anastomotic air testing of stapled colorectal anastomosis is performed by filling the pelvis with saline solution and insufflating the rectum with air through a sigmoidoscope. The presence of air bubbles indicates anastomotic leaks which are resolved during surgery. OBJECTIVE The aim of this prospective, randomized study was to perform a comparative analysis regard...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Endoscopy
دوره 48 S 01 شماره
صفحات -
تاریخ انتشار 2016