Stimulation threshold greatly affects the predictive value of intraoperative nerve monitoring.

نویسندگان

  • Daniel L Faden
  • Lisa A Orloff
  • Tokunbo Ayeni
  • Daniel S Fink
  • Katherine Yung
چکیده

OBJECTIVES/HYPOTHESIS Using a standardized, graded, intraoperative stimulation protocol, we aimed to delineate the effects of various stimulation levels applied to the recurrent laryngeal nerve on the postoperative predictive value of intraoperative nerve monitoring. STUDY DESIGN A total of 917 nerves at risk were included for analysis. Intraoperatively, patients underwent stimulation of the recurrent laryngeal nerve at 0.3, 0.5, 0.8, and 1.0 mA followed by postoperative laryngoscopy for correlation with intraoperative findings. METHODS Sensitivity, specificity, positive predictive value, and negative predictive value were calculated at each stimulation level. RESULTS Sensitivity, specificity, positive predictive value, and negative predicative values ranged from 100% to 37%, 6% to 99%, 2% to 39%, and 100% to 99%, respectively at 0.3 to 1.0 mA. No demographic variables affected sensitivity or specificity. Receiver operating characteristic analysis identified 0.5 mA as the level of stimulation that optimizes sensitivity and specificity. CONCLUSIONS The predictive value of intraoperative nerve monitoring varies greatly depending on the stimulation levels used. At low amplitudes of stimulation, nerve monitoring has high sensitivity and negative predictive value but low specificity and positive predictive value, related to the high rate of false positives. At high levels of stimulation, specificity and negative predictive value are high, sensitivity is low, and the positive predictive value rises as the rate of false negatives increase and the rate of false positives decrease. A stimulation level of 0.5 mA optimizes the predictive value of nerve monitoring; however, stimulation at multiple levels significantly improves the predictive value of intraoperative nerve monitoring. LEVEL OF EVIDENCE 2b.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute prediction of laryngeal outcome during thyroid surgery by electromyographic laryngeal monitoring.

BACKGROUND The purpose of this study was to evaluate the contribution of laryngeal intraoperative nerve monitoring (IONM) during thyroidectomy in predicting postoperative laryngeal mobility. METHODS Between 2009 and 2012, 127 patients underwent thyroidectomy, during which 216 recurrent laryngeal nerves were stimulated with suprathreshold stimulations. Laryngeal mobility was examined through d...

متن کامل

Intraoperative Neurophysiology Monitoring During Selective Dorsal Rhizotomy for Spastic Cerebral Palsy

Selective Dorsal Rhizotomy (SDR) is a neurosurgical procedure currently used as a surgical treatment of children with spasticity in their legs. In SDR, the dorsal roots from L2 to S1 or S2 is partially sectioned. The primary goal of SDR is to reduce spasticity and improve the range of movement with preservation of muscle strength. The dorsal roots involved in spasticity are identified on the ba...

متن کامل

Continuous vagal IONM prevents recurrent laryngeal nerve paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study.

OBJECTIVES/HYPOTHESIS Existing intraoperative neuromonitoring (IONM) formats stimulate the recurrent laryngeal nerve (RLN) intermittently, exposing it to risk for injury in between stimulations. We report electrophysiologic parameters of continuous vagal monitoring, utilizing a novel real-time IONM format, and relate these parameters to intraoperative surgical maneuvers that delineate nascent a...

متن کامل

Intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve during thyroid and parathyroid surgery: Experience with 1,381 nerves at risk.

OBJECTIVES The electrophysiologic responses of 1,381 recurrent laryngeal nerves (RLN) during monitored neck surgery were recorded and reviewed. STUDY DESIGN Retrospective case series. METHODS With institutional review board approval, we reviewed thyroid and other neck surgeries performed with intraoperative nerve monitoring (IONM) between the years 1995 and 2006. This list yielded consecuti...

متن کامل

Asymmetric Rectangular Waveform in Stimulation with High Frequency Alternating Current Reduces the Threshold for Neural Conduction Block

Introduction Abnormal neural impulses in the nervous system may lead to various diseases and disabilities. High frequency alternating currents (HFAC) has been used to block the propagation of such impulses and improve the symptoms or disabilities. The technique is safe, reversible, and relatively selective, and its reliability, the optimum stimulation parameters, and elimination of the onset re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Laryngoscope

دوره 125 5  شماره 

صفحات  -

تاریخ انتشار 2015