Sampled Data Automatic Generation Control of a Two Area Reheat Thermal System with Modified Area Control Error
نویسنده
چکیده
This paper deals with Automatic Generation Control (AGC) of a two area reheat thermal system with modified area control error (ACEM) considering operation of the system in the continuous-mode and that of the controller in the discrete mode. ACEM is the weighted sum of frequency deviation, tie-power deviation and inadvertent interchange energy. Studies show that the AGC-strategy based on ACEM provides constancy of frequency and tie-power flow, zero steady state error in inadvertent interchange energy and negligible error in time error accumulation in the steady state. Further the dynamic responses of the system obtained with controllers based on ACEM are close to the responses based on new area control error ( ACEN Ref [2] ) but are much superior to the corresponding responses achieved with controllers based on conventional area control error.
منابع مشابه
Optimizing the AGC system of a three-unequal-area hydrothermal system based on evolutionary algorithms
This paper focuses on expanding and evaluating an automatic generation control (AGC) system of a hydrothermal system by modelling the appropriate generation rate constraints to operate practically in an economic manner. The hydro area is considered with an electric governor and the thermal area is modelled with a reheat turbine. Furthermore, the integral controllers and electri...
متن کاملDynamic Response Analysis of Automatic Generation Control in a 2 - Area ( Reheat & Non - Reheat ) Interconnected Power System and a Scheme for Improvement of Response for the Same
Abstract: In the present work, we focus on the study of dynamic behavior of an interconnected two-area power system and a scheme for improvement of response for the same. Here, two-area system with one non-reheat thermal units & one reheat thermal units is considered. The frequency and tie-line power deviation of two units are studied using MATLAB-SIMULINK in continuous time domain and also in ...
متن کاملAutomatic Generation Control of Multi-Area Electric Energy Systems Using Modified GA
A modified Genetic Algorithm (GA) based optimal selection of parameters for Automatic Generation Control (AGC) of multi-area electric energy systems is proposed in this paper. Simulations on multi-area reheat thermal system with and without consideration of nonlinearity like governor dead band followed by 1% step load perturbation is performed to exemplify the optimum parameter search. In this ...
متن کاملAnalysis of Wind Speed Forecasting Error Effects on Automatic Generation Control Performance
The main goal of this paper is to study statistical indices and evaluate AGC indices in power system which has large penetration of the WTGs. Increasing penetration of wind turbine generations, needs to study more about impacts of it on power system frequency control. Frequency control is changed with unbalancing real-time system generation and load . Also wind turbine generations have more flu...
متن کاملDesign of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System
This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of ...