Alternatives to the mercury sphygmomanometer.

نویسندگان

  • Susan Buchanan
  • Peter Orris
  • Joshua Karliner
چکیده

The mercury sphygmomanometer was introduced over 100 years ago. Mercury, however, is a potent human neurotoxin. An international effort has developed to eliminate health-care sources of mercury--the thermometer and sphygmomanometer--and replace them with less toxic alternatives. There is concern regarding the accuracy of these alternative devices. We conducted a literature review of articles published between 1995 and 2009 evaluating the accuracy of mercury, aneroid, and oscillometric blood pressure devices. Mercury sphygmomanometers fared the best although they do not always perform as expected, failing calibration tests between 1 and 28 per cent of the time. Up to 61 per cent of aneroid sphygmomanometers failed. Recently calibrated aneroid devices performed well. Oscillometric devices were less studied and their performance was variable. All three devices showed variable performance. They should be validated before purchase and calibrated on a regular basis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mercury toxicity

Mercury is a metal found in elemental, organic, and inorganic forms in the nature. This substance is present in the composition of earth crust, soil, air, and even in some tissues of plants and sea animals. Each year nearly 3400 tons of mercury compounds are released in the environment, which 95% settle in the soil, 3% in the oceans, and 2% in the atmosphere. Different industrial products li...

متن کامل

A comparison of the random-zero and standard mercury sphygmomanometers.

Both the standard mercury sphygmomanometer and the random-zero sphygmomanometer have been used in epidemiological studies and clinical trials. Problems arise in comparing studies since, in addition to other methodological differences, the readings obtained with the random-zero sphygmomanometer have been found to be lower than those obtained with the standard mercury sphygmomanometer. In the pre...

متن کامل

مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی

Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...

متن کامل

Finger systolic pressure: its use in screening for hypertension and monitoring.

A finger sphygmomanometer was compared with a mercury column sphygmomanometer for its ability to screen for hypertension. A total of 881 patients used each machine, both in initial screening and then for monitoring. The finger sphygmomanometer had a specificity of 98.5% in routine screening as compared with 97.6% for the mercury column device. Sensitivity of the finger device was 98.2%. These f...

متن کامل

Evaluating the accuracy of an aneroid sphygmomanometer in a clinical trial setting.

BACKGROUND The mercury sphygmomanometer, the "gold" standard for blood pressure measurements, has been gradually phased out in many institutions because of environmental concerns. Our on-going clinical trial compared the use of mercury vs. aneroid sphygmomanometers, before implementing a study-wide transition to the aneroid sphygmomanometer. METHODS The Diabetes Prevention Program Outcomes St...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of public health policy

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2011