Comparison of the Beckman Auto ICS and the Syva Autolab 6000 for determination of gentamicin levels in serum.

نویسندگان

  • R H Glew
  • R A Pavuk
چکیده

Two fully automated drug-monitoring systems, the Syva Autolab 6000 and the Beckman Auto ICS, were compared in terms of accuracy, precision, speed of operation, and cost effectiveness in the determination of gentamicin levels in serum. Within-run and between-run precision for both systems were acceptable (coefficient of variation, 2.0 to 6.9%), and patient sample comparisons resulted in an intermethod correlation coefficient of 0.96. When reference samples (prepared to contain 1.2 to 10 micrograms of gentamicin per ml) were assayed, the Syva Autolab 6000 obtained concentrations within 8% of expected values, whereas the Beckman Auto ICS reported values up to 17% higher than target values. In a time and cost comparison, reagent costs for the Beckman system were ca. 50% less than for the Syva Autolab 6000; the Syva system, however, determined patient results two to three times faster than the Beckman Auto ICS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of four gentamicin and tobramycin assay procedures for clinical laboratories.

Accuracy, precision, and clinical laboratory utility of the TDX (Abbott Laboratories), Auto-ICS (Beckman Instruments, Inc.), COBAS-Bio (Roche Analytical Instruments, Inc.) with reagent kits (Syva), and EMIT (Syva) for gentamicin and tobramycin serum assay were assessed. TDX, COBAS-Bio, and EMIT analytical systems showed a proportional bias of less than 10% for recovery studies and a coefficient...

متن کامل

Comparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.

We assayed serum gentamicin and tobramycin specimens by the enzyme multiplied immunoassay technique (Syva EMIT) and the fluorescence polarization immunoassay (Abbott TDx). When interassay and intraassay control samples were evaluated, both methods gave an overall coefficient of variation of less than +/- 10%. Using patient serum samples, we obtained excellent correlation with both methods in th...

متن کامل

Rate nephelometry and radial immunodiffusion compared for measuring serum prealbumin.

We compared a rate-nephelometric method and a radial immunodiffusion (RID) assay for measurement of prealbumin (transthyretin) in 55 samples of serum from healthy children. The mean prealbumin concentration as measured by the Beckman Auto ICS nephelometer was 188 mg/L (range 128-350); the mean by RID was 221 mg/L (range 125-419). This difference was statistically significant by Student's t-test...

متن کامل

Protective effects of aqueous extract of M. Pruriens Linn. (DC) seed against gentamicin induced oxidative stress and nephrotoxicity in rats

In the present study, we investigated the effects of the aqueous extract of Mucuna pruriens against gentamicin (100 mg kg -1 per day for six days) induced oxidative stress and nephrotoxicity in rats. Administration of gentamicin to rats induced a marked renal failure, characterized by a significant increase in urine volume and serum creatinine and urea levels. There was a significant decr...

متن کامل

The Effect of Pine Cones Aqueous Extract on Renal Function in Male Rats

Background:Antioxidant effects of cypress cones extract have been previously demonstrated. In this study, the protective effect of cypress cones extract was investigated. Gentamicin, an aminoglycoside antibiotic administrated for the treatment of gram-negative bacteria infections, was used for nephrotoxicity induction. Methods: In this study, 60 wistar male ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 1985