Comparative assessment of forces generated during simulated alignment with self-ligating and conventional brackets.
نویسندگان
چکیده
The objectives of this study were to comparatively assess the magnitude and direction of forces and moments generated from different bracket systems, during the initial levelling and alignment stage of orthodontic treatment. Three types of brackets were used: Orthos2 (Ormco), Damon2 (Ormco), and In-Ovation R (GAC). The brackets were bonded on resin replicas models of a patient's crowded mandibular arch, and a 0.014 inch Damon archform CuNiTi (Ormco) wire was inserted. The model was mounted on the Orthodontic Measurement and Simulation System (OMSS) and six static measurements were taken at the initial crowded state per bracket for the lateral incisor, canine, and first premolar. A total of 10 repetitions were performed for each measurement, with new brackets and archwires used for each trial. The forces and moments generated were registered directly on the OMSS software and were statistically analyzed using a one-way analysis of variance separately for each dental arch location and force component. Group differences were further analyzed with Tukey's post hoc comparisons test at the 0.05 significance level. The lingually inclined, crowded lateral incisor presented an extrusive and buccal movement and showed the lowest force in the vertical direction, whereas the self-ligating group of brackets generated the highest force in the buccolingual direction. The moments applied by the three bracket systems followed the general trend shown for forces; in the vertical axis, the self-ligating brackets exerted lower forces than their conventional counterpart. This was modified in the buccolingual direction where, in most instances, the self-ligating appliances applied higher moments compared with the conventional bracket. In most cases, the magnitude of forces and moments ranged between 30-70 cN and 2-6 N mm, respectively. However, maximum forces and moments developed at the lateral incisor were almost four times higher than the average.
منابع مشابه
In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment
OBJECTIVE To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. METHODS Interactive self-ligating brackets with closed and o...
متن کاملComparative Evaluation of Frictional forces between different Archwire-bracket Combinations
Introduction: During sliding mechanics, frictional resistance is an important counterforce to orthodontic tooth movement; which must be controlled to allow application of light continuous forces. objective: To investigate static and kinetic frictional resistance between three orthodontic brackets: ceramic, self-ligating, and stainless steel, and three 0.019×0.025” archwires: stainless steel, ni...
متن کاملMoments generated during simulated rotational correction with self-ligating and conventional brackets.
OBJECTIVE To assess comparatively the magnitude of moments generated during rotational correction from different bracket systems during the late leveling and alignment stage of orthodontic treatment. MATERIALS AND METHODS The three types of brackets assessed were Orthos2 (ORMCO, Glendora, CA), Damon2 (ORMCO), and In Ovation-R (GAC, Bohemia, NY). The brackets were bonded on replicas made of re...
متن کاملForces released during sliding mechanics with passive self-ligating brackets or nonconventional elastomeric ligatures.
INTRODUCTION The aim of this study was to evaluate the frictional forces generated by 4 types of passive stainless steel self-ligating brackets (SLBs) and by nonconventional elastomeric ligatures (NCEL) and conventional elastomeric ligatures (CEL) during sliding mechanics. METHODS An experimental model consisting of 5 aligned stainless steel 0.022-in brackets was used to assess frictional for...
متن کاملComparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions
OBJECTIVE The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). METHODS Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four mis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2009