Diagnostic sensitivity of carbohydrate deficient transferrin in heavy drinkers

نویسندگان

  • Kevin J Fagan
  • Katharine M Irvine
  • Brett C McWhinney
  • Linda M Fletcher
  • Leigh U Horsfall
  • Lambro Johnson
  • Peter O’Rourke
  • Jennifer Martin
  • Ian Scott
  • Carel J Pretorius
  • Jacobus PJ Ungerer
  • Elizabeth E Powell
چکیده

BACKGROUND AND AIM Carbohydrate deficient transferrin (CDT) is the most specific serum biomarker of heavy alcohol consumption, defined as ≥ 350-420 g alcohol/week. Despite introduction of a standardized reference measurement technique, widespread use of CDT remains limited due to low sensitivity. The aim of this study was to determine the factors that affect diagnostic sensitivity in patients with sustained heavy alcohol intake. METHODS Patients with a self-reported history of sustained heavy alcohol consumption were recruited from the hepatology outpatient department or medical wards. Each patient was interviewed with a validated structured questionnaire of alcohol consumption and CDT analysis using the standardized reference measurement technique with high performance liquid chromatography was performed on serum collected at time of interview. RESULTS 52 patients were recruited: 19 from the hepatology outpatient department and 33 from general medical wards. Median alcohol intake was 1013 (range 366-5880) g/week over the preceding two week period. 26 patients had a diagnostic CDT based on a threshold value of %CDT > 1.7 indicating heavy alcohol consumption, yielding a sensitivity of 50%. Overweight/obesity (defined as body mass index (BMI) ≥ 25 kg/m2 in Caucasians and ≥ 23.0 kg/m2 in Asians), female gender and presence of cirrhosis were independently associated with non-diagnostic %CDT (≤ 1.7). CONCLUSIONS CDT has limited sensitivity as a biomarker of heavy alcohol consumption. Caution should be applied when ordering and interpreting %CDT results, particularly in women, patients with cirrhosis and those with an elevated BMI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ASSESSMENT AND DETECTION Clinical Characteristics of Carbohydrate-Deficient Transferrin (%Disialotransferrin) Measured by HPLC: Sensitivity, Specificity, Gender Effects, and Relationship with other Alcohol Biomarkers

Aims: The sensitivity and specificity of the relative disialotransferrin amount (%DST), considered the primary single target for measurement of the alcohol biomarker carbohydrate-deficient transferrin (CDT), were compared with the absolute CDT amount determined by the CDTect assay and with GGT and AST. Methods: Serum samples (n = 1387) were collected within the WHO/ISBRA Study on State and Trai...

متن کامل

The combined use of the early detection of alcohol consumption (EDAC) test and carbohydrate-deficient transferrin to identify heavy drinking behaviour in males.

The aim of this study was to determine the efficacy of the combined use of carbohydrate-deficient transferrin (CDT) and the Early Detection of Alcohol Consumption (EDAC) test to assess heavy drinking in a population of males (n = 187) drinking an average of 20 drinks per day. Heavy drinkers (n = 138) and light drinkers (n = 49) were analysed in three ways: using the EDAC test alone, using the C...

متن کامل

Confirming Diagnosis of Hazardous and Harmful Alcohol

Diagnostic accuracy of a computer assisted diagnostic system compared to conventional markers of alcoholism. Netherlands (van Lambalgen, professor of logic and artificial intelligence). Acknowledgements All laboratory tests, except carbohydrate-deficient transferrin (CDT) were performed in the ABSTRACT Context Conventional tests for alcoholism have good screening properties for detecting hazard...

متن کامل

Carbohydrate-deficient transferrin quantified by HPLC to determine heavy consumption of alcohol.

We developed a new fully automated ion-exchange chromatographic method for quantitating carbohydrate-deficient transferrin (CDT) on a Mono Q column. Quantitation relies on the selective absorbance of the iron-transferrin complex at 460 nm. Transferrin isoforms deficient in sialic acid, with pIs 5.7 and 5.9, can easily be separated and quantitated as a percentage of the total transferrin. This m...

متن کامل

Carbohydrate-deficient Transferrin as a Marker of Heavy Drinking in Korean Males

This study was performed to evaluate the usefulness of carbohydrate-deficient transferrin (CDT) as a marker of heavy drinking in Korean males. The subjects (143 Korean males) were classified into 2 groups according to the amount of drinking, moderate drinkers (72 individuals) who drank 14 drinks or less per week and heavy drinkers (71 individuals) who drank more than 14 drinks per week. Using %...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014