Accuracy of acoustic respiration rate monitoring in pediatric patients.
نویسندگان
چکیده
BACKGROUND Rainbow acoustic monitoring (RRa) utilizes acoustic technology to continuously and noninvasively determine respiratory rate from an adhesive sensor located on the neck. OBJECTIVE We sought to validate the accuracy of RRa, by comparing it to capnography, impedance pneumography, and to a reference method of counting breaths in postsurgical children. METHODS Continuous respiration rate data were recorded from RRa and capnography. In a subset of patients, intermittent respiration rate from thoracic impedance pneumography was also recorded. The reference method, counted respiratory rate by the retrospective analysis of the RRa, and capnographic waveforms while listening to recorded breath sounds were used to compare respiration rate of both capnography and RRa. Bias, precision, and limits of agreement of RRa compared with capnography and RRa and capnography compared with the reference method were calculated. Tolerance and reliability to the acoustic sensor and nasal cannula were also assessed. RESULTS Thirty-nine of 40 patients (97.5%) demonstrated good tolerance of the acoustic sensor, whereas 25 of 40 patients (62.5%) demonstrated good tolerance of the nasal cannula. Intermittent thoracic impedance produced erroneous respiratory rates (>50 b·min(-1) from the other methods) on 47% of occasions. The bias ± SD and limits of agreement were -0.30 ± 3.5 b·min(-1) and -7.3 to 6.6 b·min(-1) for RRa compared with capnography; -0.1 ± 2.5 b·min(-1) and -5.0 to 5.0 b·min(-1) for RRa compared with the reference method; and 0.2 ± 3.4 b·min(-1) and -6.8 to 6.7 b·min(-1) for capnography compared with the reference method. CONCLUSIONS When compared to nasal capnography, RRa showed good agreement and similar accuracy and precision but was better tolerated in postsurgical pediatric patients.
منابع مشابه
Comparison of Acoustic Respiration Rate, Impedance Pneumography and Capnometry Monitors for Respiration Rate Accuracy and Apnea Detection during GI Endoscopy Anesthesia
Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized patients undergoing gastrointestinal endoscopy procedures. Design: Prospective observational study. Setting: Endoscopy procedures laboratory. Patients: 98 patients scheduled for uppe...
متن کاملClinical Predictors of Intensive Care Unit Admission for Asthmatic Children
IntroductionChildren with severe asthma attack are a challenging group of patients who could be difficult to treat and leading to significant morbidity and mortality. Asthma attack severity is qualitatively estimated as mild, moderate and severe attacks and respiratory failure based on conditions such as respiration status, feeling of dyspnea, and the degree of unconsciousness. part of which ar...
متن کاملComparison of Anesthetic Techniques on Outcomes of Pediatric Rigid Bronchoscopy for Foreign Body Removal
Background Although both methods of spontaneous respiration and controlled ventilation during anesthesia are safe and effective for managing children with foreign body aspiration, there is no consensus from the literature as to which technique is optimal. This study aimed to determine the outcomes of anesthetic techniques in pediatric rigid bronchoscopy for foreign body removal. Materials and M...
متن کاملFeasibility Study of Real-time and Automated Monitoring of Iranian Rivers using 50-kHz Fluvial Acoustic Tomography System
Acoustic Tomography (AT) technique is an innovative method for real-time river monitoring. In this study, not only the accuracy of flow velocity measurement using 50 kHz AT system which is appropriate for narrow rivers (most Iranian rivers) is evaluated, but also its performance is compared with 30 kHz one which is used in wide rivers. The comparison results showed that the velocity resolutions...
متن کاملDiagnostic Accuracy of Growth Rate in Differentiating Etiologies of Short Stature in Children
Background Short stature is a manifestation of a wide variety of conditions that some of which may be amenable to timely treatment and a suboptimal growth rate may be an early marker pointing to the cause of growth retardation. This study was conducted to evaluate the diagnostic utility of growth rate in differential diagnosis of children with short stature. Materials and Methods All children ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Paediatric anaesthesia
دوره 23 12 شماره
صفحات -
تاریخ انتشار 2013