Endothelial damage from intraocular lens insertion.

نویسندگان

  • E Kaufman
  • J I Katz
چکیده

Previous studies have shown that approximately 40 per cent of the corneal endothelial cells can be lost at the time of intraocular lens insertion. Momentary contact between the methacrylate surface and the endothelial cells causes an adhesion between these surfaces and results in extensive cell damage upon separation of the surfaces. This type of damage appears to be due to a biophysical interaction between these surfaces and may be avoidable by altering the surface of the lens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new technique for the vital staining of the corneal endothelium

tion and irrigation of the anterior chamber, and although lens design with surface protuberances may be of some importance, it is clear that a biophysical interaction between methacrylate and the corneal endothelial surface produces extensive cell damage. It appears that the methacrylate adheres instantaneously to the endothelial surface, and with separation of the two surfaces the anterior mem...

متن کامل

Lens vacuoles during phakic intraocular lens implantation

Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed sur...

متن کامل

Minimizing corneal endothelial damage due to intraocular lens contact.

Previous studies have shown that momentary contact between a methylmethacrylate intraocular lens and the corneal endothelial cells results in extensive cell damage. This contact damage is reduced by coating the pseudophake with various solutions prior to contact with the endothelium.

متن کامل

Air-assisted Descemet-stripping automated endothelial keratoplasty with posterior chamber iris-fixation of aphakic iris-claw intraocular lens.

We report a combination of surgical techniques during Descemet-stripping automated endoithelial keratoplasty and intraocular lens (IOL) exchange in patients with pseudophakic bullous keratopathy and angle-supported anterior chamber IOLs. During this procedure, the anterior chamber IOL is exchanged for a posterior chamber iris-claw IOL enclavated to the posterior iris; the anterior chamber is ke...

متن کامل

The effect of capsular tension ring on posterior capsular opacity in cataract surgery.

This study was performed to evaluate the efficacy and safety of the capsular tension ring on posterior capsular opacity in comparison with cases undergoing intraocular lens (IOL) implantation alone. We analyzed 127 eyes which had undergone cataract surgery, including capsular tension ring insertion, along with 127 eyes which had undergone IOL implantation alone by the same surgeon from Septembe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 15 12  شماره 

صفحات  -

تاریخ انتشار 1976