Noninterferometric phase-contrast images obtained with incoherent x-ray sources.

نویسندگان

  • Alessandro Olivo
  • Konstantin Ignatyev
  • Peter R T Munro
  • Robert D Speller
چکیده

We report on what are believed to be the first full-scale images obtained with the coded aperture concept, which uses conventional x-ray sources without the need to collimate/aperture their output. We discuss the differences in the underpinning physical principles with respect to other methods, and explain why these might lead to a more efficient use of the source. In particular, we discuss how the evaluation of the first imaging system provided promising indications on the method's potential to detect details invisible to conventional absorption methods, use an increased average x-ray energy, and reduce exposure times-all important aspects with regards to real-world implementations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase and absorption retrieval using incoherent X-ray sources.

X-ray phase contrast imaging has overcome the limitations of X-ray absorption imaging in many fields. Particular effort has been directed towards developing phase retrieval methods: These reveal quantitative information about a sample, which is a requirement for performing X-ray phase tomography, allows material identification and better distinction between tissue types, etc. Phase retrieval se...

متن کامل

Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources

X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics and materials science. For biological tissue samples, polymers or fibre composites, however, the use of conventional X-ray radiography is limited due to their weak absorption. This is resolved at highly brilliant X-ray synchrotron or micro-focus sources by using phase-sensitive imaging methods to improve the cont...

متن کامل

Propagation-based x-ray phase-contrast imaging with broad focus conventional x-ray sources

A propagation-based x-ray phase-contrast imaging (PBI) setup using a conventional x-ray source (LFF Cu target) is presented. A virtual x-ray source of 40 x 50 μm was created by using, horizontally, a 6 take-off angle (with the x-ray tube working in the line focus geometry) and, vertically, a 50 μm slit . The sample was set 12 m from the source. Propagation-based x-ray phase-contrast (PB) image ...

متن کامل

A STUDY OF GAMMA RAY EXPOSURE BUILDUP FACTORS IN STRATIFIED SHIELDS FOR POINT ISOTROPIC SOURCES, INCLUDING THE EFFECTS OF INCOHERENT AND COHERENT SCATTERING

The effects of including incoherent (bound-electron) and coherent (Rayleigh) scattering in exposure buildup factor calculations for point isotropic gamma ray sources, penetrating a two-layer water-lead shield have been investigated in the gamma ray energy (E?) range of 40 keV to 3 MeV. Incoherent scattering decreases the values of these factors in both layers up to E? ~ 200 keV and the effect i...

متن کامل

Factors Affecting In-line Phase Contrast Imaging with a Laboratory Microfocus X-ray Source

An in-line method of phase contrast imaging is investigated using a polychromatic laboratorybased microfocus X-ray source. The effect of source size is considered, and by introducing water into the imaging path the influence of water on the phase contrast is determined. The results confirm that good phase contrast images can be achieved using a polychromatic laboratory-based X-ray source, and d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2011