Development of a Radial Pulse Tonometric (RPT) Sensor with a Temperature Compensation Mechanism
نویسندگان
چکیده
Several RPT sensors have been developed to acquire objective and quantitative pulse waves. These sensors offer improved performance with respect to pressure calibration, size and sensor deployment, but not temperature. Since most pressure sensors are sensitive to temperature, various temperature compensation techniques have been developed, but these techniques are largely inapplicable to RPT sensors due to the size restrictions of the sensor, and incompatibility between the compensation techniques and the RPT sensor. Consequently, in this paper a new RPT sensor comprising six piezoresistive pressure sensors and one thermistor has been developed through finite element analysis and then a suitable temperature compensation technique has been proposed. This technique compensates for temperature variations by using the thermistor and simple compensation equations. As verification of the proposed compensation technique, pulse waves of all types were successfully compensated for temperature changes.
منابع مشابه
Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse
The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a c...
متن کاملCaution using brachial systolic pressure to calibrate radial tonometric pressure waveforms: lessons from invasive study.
Caution Using Brachial Systolic Pressure to Calibrate Radial Tonometric Pressure Waveforms: Lessons From Invasive Study To the Editor: We were very interested to read the recent article by Segers et al1 that prompted the correspondence from O’Rourke and Takazawa,2 who were concerned about the reliability of brachial artery tonometry and the lack of relevant invasive data, as well as the subsequ...
متن کاملNew Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices
An accurate assessment of the pulse depth in pulse diagnosis is vital to determine the floating and sunken pulse qualities (PQs), which are two of the four most basic PQs. In this work, we proposed a novel model of assessing the pulse depth based on sensor displacement (SD) normal to the skin surface and compared this model with two previous models which assessed the pulse depth using contact p...
متن کاملA Linearization Time-Domain CMOS Smart Temperature Sensor Using a Curvature Compensation Oscillator
This paper presents an area-efficient time-domain CMOS smart temperature sensor using a curvature compensation oscillator for linearity enhancement with a -40 to 120 °C temperature range operability. The inverter-based smart temperature sensors can substantially reduce the cost and circuit complexity of integrated temperature sensors. However, a large curvature exists on the temperature-to-time...
متن کاملFlexible PZT Thin Film Tactile Sensor for Biomedical Monitoring
This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse top...
متن کامل