X-ray analog pixel array detector for single synchrotron bunch time-resolved imaging.

نویسندگان

  • Lucas J Koerner
  • Sol M Gruner
چکیده

Dynamic X-ray studies can reach temporal resolutions limited by only the X-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures successive pulses. Fundamental tests of noise and linearity as well as high-speed laser measurements are shown. The detector resolved individual bunch trains at the Cornell High Energy Synchrotron Source at levels of up to 3.7 × 10(3) X-rays per pixel per train. When applied to turn-by-turn X-ray beam characterization, single-shot intensity measurements were made with a repeatability of 0.4% and horizontal oscillations of the positron cloud were detected.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Speed X-ray Imaging with the Keck Pixel Array Detector (Keck PAD) for Time-Resolved Experiments at Synchrotron Sources

Modern storage rings are readily capable of providing intense x-ray pulses, tens of picoseconds in duration, millions of times per second. Exploiting the temporal structure of these x-ray sources opens avenues for studying rapid structural changes in materials. Many processes (e.g. crack propagation, deformation on impact, turbulence, etc.) differ in detail from one sample trial to the next and...

متن کامل

Development of a two-dimensional virtual-pixel X-ray imaging detector for time-resolved structure research.

An interpolating two-dimensional X-ray imaging detector based on a single-photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the micro s time domain. The prototype detector has been tested at the SAXS (small-angle X-ray scattering) beamline at ELETTRA synchrotron light sourc...

متن کامل

Spectrometric Performances of CdTe and CdZnTe Spectrometric Semiconductor Detector Arrays at High X-Ray Flux

The development of a novel energy resolved fast Xray imaging detector is reported. The device is based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) detectors coupled to a custom designed 16-channel fast spectroscopy front-end electronic circuit. For each channel, a fast Analog to Digital Converter (ADC) continuously digitizes the signal from the detector pixel. A F...

متن کامل

Picosecond time-resolved laser pump/X-ray probe experiments using a gated single-photon-counting area detector.

The recent developments in X-ray detectors have opened new possibilities in the area of time-resolved pump/probe X-ray experiments; this article presents the novel use of a PILATUS detector to achieve X-ray pulse duration limited time-resolution at the Advanced Photon Source (APS), USA. The capability of the gated PILATUS detector to selectively detect the signal from a given X-ray pulse in 24 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 18 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2011