Defining the ideal femtosecond laser capsulotomy
نویسندگان
چکیده
PURPOSE We define the ideal anterior capsulotomy through consideration of capsular histology and biomechanics. Desirable qualities include preventing posterior capsular opacification (PCO), maintaining effective lens position (ELP) and optimising capsular strength. METHODS Laboratory study of capsular biomechanics and literature review of histology and published clinical results. RESULTS Parameters of ideal capsulotomy construction include complete overlap of the intraocular lens to prevent PCO, centration on the clinical approximation of the optical axis of the lens to ensure concentricity with the capsule equator, and maximal capsular thickness at the capsulotomy edge to maintain integrity. CONCLUSIONS Constructing the capsulotomy centred on the clinical approximation of the optical axis of the lens with diameter 5.25 mm optimises prevention of PCO, consistency of ELP and capsular strength.
منابع مشابه
Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery.
PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...
متن کاملIdeal parameters for femto-second laser-assisted anterior capsulotomy: Animal studies
In femtosecond laser-assisted cataract surgery, the parameter such as horizontal spot spacing and energy level can be adjusted. Although there have been several studies reported on various laser systems, showing the effects of varying energy levels and horizontal spot spacing on lens capsulotomy cut edges, none have been reported on the Catalys laser system (Abbott Medical Optics, Inc., Santa A...
متن کاملComparison of Manual, Femtosecond Laser, and Precision Pulse Capsulotomy Edge Tear Strength in Paired Human Cadaver Eyes.
PURPOSE To compare the anterior lens capsulotomy edge tear strength created by manual continuous curvilinear capsulorhexis (CCC), femtosecond laser capsulotomy (FSLC), and a new automated precision pulse capsulotomy (PPC) device. DESIGN A 3-arm study in paired human cadaver eyes. PARTICIPANTS A total of 44 eye specimens from 22 donors in the United States. METHODS Capsulotomy was performe...
متن کاملFemtosecond laser capsulotomy.
PURPOSE To evaluate a femtosecond laser system to create the capsulotomy. SETTING Porcine and cadaver eye studies were performed at OptiMedica Corp., Santa Clara, California, USA; the human trial was performed at the Centro Laser, Santo Domingo, Dominican Republic. DESIGN Experimental and clinical study. METHODS Capsulotomies performed by an optical coherence tomography-guided femtosecond...
متن کاملComparative evaluation of femtosecond laser-assisted cataract surgery and conventional phacoemulsification in white cataract
PURPOSE To compare femtosecond laser-assisted capsulotomy with conventional manual capsulorhexis in cases of white cataract. PATIENTS AND METHODS The prospective comparative study enrolled 80 eyes (80 patients) with white cataract that underwent either femtosecond laser-assisted cataract surgery (Group I, n=40) or conventional manual phacoemulsification (Group II, n=40) at a tertiary care oph...
متن کامل