Bayesian Artifact Reduction on Ecg Acquired during Mri

نویسندگان

  • Julien Oster
  • Olivier Pietquin
  • Michel Kraemer
  • Jacques Felblinger
چکیده

Electrocardiogram (ECG) is required during Magnetic Resonance Imaging (MRI) for two reasons, patient monitoring and MRI sequence synchronization for cardiovascular imaging. The MRI environment severely distorts ECG signals. The Magnetic Field Gradients (MFG) especially induce artifacts, which make ECG analysis during MRI acquisition challenging. Specific signal processing is thus required. An MFG artifact modeling has been proposed for their suppression. However the resulting techniques do not take the ECG signals into account during the model parameter estimation. Recently, ECG denoising based on an artificial ECG model and nonlinear Bayesian filtering has been presented. In this paper, a new MFG artifact suppression method based on nonlinear Bayesian filtering and the unification of the ECG and MFG models is proposed. This new approach enables accurate patient monitoring and outperforms state-of-the-art methods in terms of both QRS detection quality and signal to noise ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Field Gradient Artifact Reduction on Ecg for Improved Triggering

INTRODUCTION: Due to heart motion, cardiac MRI is made difficult and image acquisitions have to be synchronized with heart activity to suppress cardiac motion artifacts. Electrocardiogram (ECG) is therefore the state-of-the-art signal [1], each MRI acquisition being launched after a fixed delay following a QRS complex detection. The complex MRI environment highly distorts ECG signals, due to th...

متن کامل

ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner.

Electroencephalogram (EEG) data acquired in the MRI scanner contains significant artifacts, one of the most prominent of which is ballistocardiogram (BCG) artifact. BCG artifacts are generated by movement of EEG electrodes inside the magnetic field due to pulsatile changes in blood flow tied to the cardiac cycle. Independent Component Analysis (ICA) is a statistical algorithm that is useful for...

متن کامل

A Bayesian approach for image denoising in MRI

Magnetic Resonance Imaging (MRI) is a notable medical imaging technique that is based on Nuclear Magnetic Resonance (NMR). MRI is a safe imaging method with high contrast between soft tissues, which made it the most popular imaging technique in clinical applications. MR Imagechr('39')s visual quality plays a vital role in medical diagnostics that can be severely corrupted by existing noise duri...

متن کامل

A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses

This study reports on a novel method to detect and reduce the contribution of movement artifact (MA) in electrocardiogram (ECG) recordings gathered from horses in free movement conditions. We propose a model that integrates cardiovascular and movement information to estimate the MA contribution. Specifically, ECG and physical activity are continuously acquired from seven horses through a wearab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009