Automated border detection in three-dimensional echocardiography: principles and promises.

نویسندگان

  • K Y Esther Leung
  • Johan G Bosch
چکیده

Several automated border detection approaches for three-dimensional echocardiography have been developed in recent years, allowing quantification of a range of clinically important parameters. In this review, the background and principles of these approaches and the different classes of methods are described from a practical perspective, as well as the research trends to achieve a robust method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of cardiovascular magnetic resonance with real-time three-dimensional echocardiography and the right ventricular automated systolic index in the assessment of the right ventricular function

Background The right ventricular (RV) function has an important diagnostic value in many cardiopulmonary diseases and is a predictor for the long-term outcome. Cardiovascular magnetic resonance (CMR) is the gold-standard for the RV quantification as the complex anatomy of the RV, i.e. its crescentic shape, impedes reliable measurement by two-dimensional echocardiography (EC). Yet, CMR or real-t...

متن کامل

Dynamic three-dimensional echocardiography combined with semi-automated border detection offers advantages for assessment of resynchronization therapy

Simultaneous electrical stimulation of both ventricles in patients with interventricular conduction disturbance and advanced heart failure improves hemodynamics and results in increased exercise tolerance, quality of life. We have developed a novel technique for the assessment and optimization of resynchronization therapy. Our approach is based on transthoracic dynamic three-dimensional (3D) ec...

متن کامل

A New Algorithm for Skin Lesion Border Detection in Dermoscopy Images

Background: With advances in medical imaging systems, digital dermoscopy has become one of the major imaging modalities in the analysis of skin lesions. Thus, automated segmentation or border detection has a great impact on the subsequent steps of skin cancer computer-aided diagnosis using demoscopy images. Since dermoscopy images suffer from artifacts such as shading and hair, there is a need ...

متن کامل

Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging

OBJECTIVE Left atrial size is an important marker for adverse cardiovascular events. There is general consensus that left atrial volume index (LAVI) is the best measurement of size. The current LAVI measurement techniques are laborious. Semi-automated measurement with a 3-dimensional echocardiography (3DE) system may be a practical clinical alternative to measure LAVI, but it has not been adequ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2010