Biomechanical analysis of pin placement for pediatric supracondylar humerus fractures: does starting point, pin size, and number matter?

نویسندگان

  • Hilton Phillip Gottschalk
  • Daljeet Sagoo
  • Diana Glaser
  • Josh Doan
  • Eric W Edmonds
  • John Schlechter
چکیده

BACKGROUND Several studies have examined the biomechanical stability of smooth wire fixation constructs used to stabilize pediatric supracondylar humerus fractures. An analysis of varying pin size, number, and lateral starting points has not been performed previously. METHODS Twenty synthetic humeri were sectioned in the midolecranon fossa to simulate a supracondylar humerus fracture. Specimens were all anatomically reduced and pinned with a lateral-entry configuration. There were 2 main groups based on specific lateral-entry starting point (direct lateral vs. capitellar). Within these groups pin size (1.6 vs. 2.0 mm) and number of pins (2 vs. 3) were varied and the specimens biomechanically tested. Each construct was tested in extension, varus, valgus, internal, and external rotation. Data for fragment stiffness (N/mm or N mm/degree) were analyzed with a multivariate analysis of variance and Bonferroni post hoc analysis (P<0.05). RESULTS The capitellar starting point provided for increased stiffness in internal and external rotation compared with a direct lateral starting point (P<0.05). Two 2.0-mm pins were statistically superior to two 1.6-mm pins in internal and external rotation. There was no significant difference found comparing two versus three 1.6-mm pins. CONCLUSIONS The best torsional resistances were found in the capitellar starting group along with increased pin diameter. The capitellar starting point enables the surgeon to engage sufficient bone of the distal fragment and maximizes pin separation at the fracture site. In our anatomically reduced fracture model, the addition of a third pin provided no biomechanical advantage. CLINICAL RELEVANCE Consider a capitellar starting point for the more distally placed pin in supracondylar humerus fractures, and if the patient's size allows, a larger pin construct will provide improved stiffness with regard to rotational stresses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter Study of Pin Site Infections and Skin Complications Following Pinning of Pediatric Supracondylar Humerus Fractures

INTRODUCTION Pediatric supracondylar humerus fractures are the most common elbow fractures in pediatric patients. Surgical fixation using pins is the primary treatment for displaced fractures. Pin site infections may follow supracondylar humerus fracture fixation; the previously reported incidence rate in the literature is 2.34%, but there is significant variability in reported incidence rates ...

متن کامل

Pediatric Supracondylar HumerusFractures: Are Medial Pins Indicated?

Background: Pediatric supracondylar humerus fractures are the most common elbow fractures in children. Operative management includes closed reduction and placement of 2 to 3 laterally based pins. Occasionally, a medial pin is used to create a crossed fixation pattern, despite risk of nearly 10% iatrogenic ulnar nerve injury. The objective of this study was to assess the trends and outcomes in t...

متن کامل

Increased pin diameter improves torsional stability in supracondylar humerus fractures: an experimental study.

BACKGROUND Pediatric supracondylar humerus fractures are the most common elbow fractures seen in children, and account for 16 % of all pediatric fractures. Closed reduction and percutaneous pin fixation is the current treatment technique of choice for displaced supracondylar fractures of the distal humerus in children. The purpose of this study was to determine whether pin diameter affects the ...

متن کامل

Biomechanical analysis of supracondylar humerus fracture pinning for slightly malreduced fractures.

BACKGROUND The most common position of malreduced type III supracondylar humerus (SCH) fractures is internal rotation and medial collapse of the distal fragment. The purpose of this study was to determine the effect of SCH fracture rotational deformity on stability with various pin configurations. Specifically, is the biomechanical stability lost when an SCH fracture is pinned in slight malredu...

متن کامل

Management of pediatric type III supracondylar humerus fractures in the United States: results of a national survey of pediatric orthopaedic surgeons.

BACKGROUND Supracondylar humerus fractures are common injuries in the pediatric population. The most severe, type III injuries, have seen the most debate on treatment regimens. Traditionally, these fractures were treated as surgical emergencies, most often fixed with percutaneous pinning in a cross-pin configuration. The recent literature shows that delayed fixation is comparable to emergent fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric orthopedics

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 2012