Exploring Test–Retest Variability Using High-Resolution Perimetry

نویسندگان

  • Takuya Numata
  • Ted Maddess
  • Chota Matsumoto
  • Sachiko Okuyama
  • Shigeki Hashimoto
  • Hiroki Nomoto
  • Yoshikazu Shimomura
چکیده

PURPOSE Test-retest variability (TRV) of visual field (VF) data seriously degrades our capacity to recognize true VF progression. We conducted repeated high-resolution perimetry with a test interval of 0.5° to investigate the sources of TRV. In particular, we examined whether the spatial variance of the observed sensitivity changes or if their absolute magnitude was of more importance. METHODS Sixteen eyes of 16 glaucoma patients were each tested three times at 61 VF locations along the superior-temporal 45° meridian using a modified protocol of the Octopus 900 perimeter. TRV was quantified as the standard deviation of the repeats at each point (retest-SD). We also computed the mean sensitivity at each point (retest-MS) and the running spatial-SD along the tested meridian. Multiple regression models investigated whether any of those variables (and also age, sex, and VF eccentricity) were significant independent determinants of TRV. RESULTS The main independent determinants of TRV were the retest-MS at -0.04 dB TRV/dB loss (P < 0.0001, t-statistic 5.05), and the retest-SD at 0.47 dB spatial variance/dB loss (P < 0.0001, t-statistic 12.5). CONCLUSIONS The larger effect for the spatial-SD suggested that it was perhaps a stronger determinant of TRV than scotoma depth per se. This might support the hypothesis that interactions between small perimetric stimuli, rapidly varying sensitivity across the field, and normal fixational jitter are strong determinants of TRV. TRANSLATIONAL RELEVANCE Our study indicates that methods that might reduce the effects of jagged sensitivity changes, such as increasing stimulus size or better gaze tracking, could reduce TRV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of high-pass resolution perimetry in normals and patients with idiopathic intracranial hypertension.

High-pass resolution perimetry, or the "ring test," is a recently developed type of acuity perimetry. To determine its test-retest variability, we studied 10 normals and 10 patients with idiopathic intracranial hypertension (IIH) by testing both eyes four separate times. There was no increase in variability from the center out to 21 degrees of visual field eccentricity. However, there was a sig...

متن کامل

Test-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects.

PURPOSE To compare the test-retest variability characteristics of frequency-doubling perimetry, a new perimetric test, with those of conventional perimetry in glaucoma patients and normal control subjects. METHODS The study sample contained 64 patients and 47 normal subjects aged 66.16+/-11.86 and 64.26+/-7.99 years (mean +/- SD), respectively. All subjects underwent frequency-doubling perime...

متن کامل

Test-retest variability of multifocal visual evoked potential and SITA standard perimetry in glaucoma.

PURPOSE To investigate the test-retest variability of multifocal visual evoked potential (mfVEP) and threshold perimetry in glaucoma, and to examine the relationship between the two techniques. METHODS Data were recorded using the AccuMap mfVEP and SITA standard program of the Humphrey Field Analyzer. Data were obtained twice within a 4-week period from both eyes of 74 patients with varying a...

متن کامل

Repeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.

PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...

متن کامل

Optimizing Contrast Sensitivity Perimetry for Clinical Use

Perimetric testing is used clinically to detect visual field abnormalities and to monitor changes during the course of management. Conventional automated perimetry (CAP), which employs small (0.43 degree) targets (Fig. 1), is hampered by high test-retest variability. Consequently, many tests are required in order to determine whether a patient is stable or progressing. Decreasing test-retest va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017