Occurrence of coring in insulin vials and possibility of rubber piece contamination by self-injection.
نویسندگان
چکیده
Coring is reported to occur because rubber pieces are shaved off from a rubber stopper when a needle is inserted into the rubber stopper of transfusion liquid formulation. We verified whether coring really occurs in insulin vials of self-injecting patients. We collected insulin cartridges from 30 hospitalized patients and used the primary injection (trial injection), the secondary injection and the cartridge remaining preparation as samples. We observed the rubber pieces using a microscope and measured the shape, number of pieces. The occurrence rate of coring was 73% for the primary injection, 47% for the secondary injection and 97% for the cartridge remaining preparation. The rubber pieces in the primary injection and the secondary injection which went through the needle are mostly in aggregate shape and the rubber pieces in the cartridge remaining preparation which did not go through the needle are mostly in needle-like shape. A number of small rubber pieces are found in both the primary injection and the secondary injection, indicating a high possibility that rubber pieces may be injected under subcutaneous tissue. The coring is considered to occur because needles are repeatedly inserted and rotated at the same spot. It is required to improve the structure to mount a needle to the pen-type injector in future. Coring is a very serious problem from the medical and pharmaceutical points of view. Further study should be made on the implication to latex allergy and lipodystrophy.
منابع مشابه
Bacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran
There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...
متن کاملBacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran
There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...
متن کامل[Research regarding proper use of insulin in diabetes patients].
In treating diabetes over the long term, controlling the daily life is very important and cannot be neglected. In particular, the patient's awareness and practice of their treatment had a great influence on their treatment. However, there has been very little scientific research done with regard to how much the patient understands the instructions about taking their medicine and whether they ac...
متن کاملبررسی نتایج استفاده مجدد از سرنگهای یک بار مصرف انسولین در بیماران وابسته به انسولین مراجعه کننده به درمانگاه شهید مطهری شیراز
Background: In spite of a high risk of infection, multiple usages of disposable insulin syringes among diabetic patients is quite common. The present study was designed to assess the outcome of multiple usages of disposable insulin syringes in insulin dependent patients referring to Shahid Motahari clinic in Shiraz . Materials and methods: For this descriptive study, through a random sampling m...
متن کاملPotential foreign body emboli associated with botulinum toxin A injections.
Although the injection of Botox Cosmetic for the treatment of dynamic rhytids is safe and effective, there is a potential risk for foreign body embolization. This case report documents the presence of a rubber particle in the reconstituted Botox product. Although the risk of embolization is thought to be very small because it is unlikely that the particle could be injected through most needle o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan
دوره 121 6 شماره
صفحات -
تاریخ انتشار 2001