Comparison of rowing on a concept 2 stationary and dynamic ergometer.

نویسندگان

  • Aaron Benson
  • Julianne Abendroth
  • Deborah King
  • Thomas Swensen
چکیده

Biomechanical and physiological responses to rowing 1000 m at a power output equivalent to a 2000 m race were compared in 34 collegiate rowers (17 women, 17 men) rowing on a stationary and dynamic Concept 2 ergometer. Stroke ratio, peak handle force, rate of force development, impulse, and respiratory exchange ratio decreased by 15.7, 14.8, 10.9, 10.2 and 1.9%, respectively, on the dynamic ergometer. In contrast, percent time to peak force and stroke rate increased by 10.5 and 12.6%, respectively, during dynamic ergometry; the changes in stroke rate and impulse were greater for men than women. Last, VO2 was 5.1% higher and efficiency 5. 3% lower on the dynamic ergometer for men. Collegiate rowers used higher stoke rates and lower peak stroke forces to achieve a similar power output while rowing at race pace on the dynamic ergometer, which may have increased the cardiopulmonary demand and possibly reduced force production in the primary movers. Differences were more pronounced in males than females; this dichotomy may be more due to dynamic ergometer familiarity than sex. Key pointsWhen rowing at a constant power output, all rowers used higher stroke rates and lower stroke forces on the Concept 2 Dynamic ergometer as compared to the Concept 2 Stationary ergometer.When rowing at a constant power output, cardiopulmonary demand was higher for all rowers, as measured by heart rate, on the Concept 2 Dynamic ergometer as compared to the Concept 2 Stationary ergometer.When rowing at a constant power output, efficiency was lower for male rowers on the Concept 2 Dynamic ergometer as compared to the Concept 2 Stationary ergometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scaling concept II rowing ergometer performance for differences in body mass to better reflect rowing in water.

We investigated whether the concept II indoor rowing ergometer accurately reflects rowing on water. Forty-nine junior elite male rowers from a Great Britain training camp completed a 2000 m concept II model C indoor rowing ergometer test and a water-based 2000 m single-scull rowing test. Rowing speed in water (3.66 m/s) was significantly slower than laboratory-based rowing performance (4.96 m/s...

متن کامل

A comparison of kinematics and performance measures of two rowing ergometers.

Rowing injuries have been attributed to poor technique, suggesting a need to understand the mechanics of rowing and the influence on technique of different training regimes and ergometers. The aims of this study were to investigate the repeatability of the kinematics of the lumbopelvic region during rowing and to compare these kinematics between rowing on two different ergometers. An electromag...

متن کامل

Reliability of power output during rowing changes with ergometer type and race distance.

Coaches, sport scientists and researchers assess rowing performance on-water and on a variety of ergometers. Ergometers are frequently used because of the easier assessment environment. However, there is limited information on the ability of rowers to reproduce mean power or time-trial time when using different rowing ergometers (Concept II and RowPerfect) or completing tests over different dis...

متن کامل

Physiological responses to exercise on different models of the concept II rowing ergometer.

PURPOSE The Concept II model C (IIC) rowing ergometer was replaced by the Concept II model D (IID), but the design modifications of the updated ergometer might alter resistance characteristics and rowing technique, thereby potentially influencing ergometer test results. This study evaluated the physiological response to rowing on the IIC and IID ergometers during a submaximal progressive increm...

متن کامل

Muscle Synergy of Collegiate Rowers During 6 Min Maximal Rowing on Fixed and Slides Ergometer

The purpose of this study was to evaluate the muscle synergy of collegiate rowers during 6 min maximal rowing on different stretcher mechanisms: fixed (FE) and slides ergometer (SE). The association of muscle synergy to rowing economy and physiological variables was further quantify by statistical analysis. Method: Ten collegiate rowers were recruited at the end of their competitive season. Mus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of sports science & medicine

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 2011