Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis
نویسندگان
چکیده
Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiographs of the hip joint. Methods: Standing and supine plain anteroposterior radiographs of 62 hip joints in which cementless total hip arthroplasty was performed were examined for polyethylene linear wear rate (mm/year), pelvic inclination, and radiological inclination and anatomic anteversion of the acetabular component. Results: All correlation coefficients of measurements of polyethylene linear wear, pelvic inclination angle, anatomical anteversion angle and radiological inclination angle were calculated highly. And by the three-dimensional numerical analysis, anatomic anteversion of the acetabular component had at least some effect on the degree of polyethylene wear. Conclusion: This study suggests that increased anteversion of the acetabular component reduces polyethylene linear wear in metal-on-polyethylene total hiparthroplasty.
منابع مشابه
Comparison of native anatomy with recommended safe component orientation in total hip arthroplasty for primary osteoarthritis.
BACKGROUND The adverse consequences of impingement, dislocation, and implant wear have stimulated increasing interest in accurate component orientation in total hip arthroplasty and hip resurfacing. The aims of the present study were to define femoral and acetabular orientation in a cohort of patients with primary hip osteoarthritis and to determine whether the orientation of their native hip j...
متن کاملPolyethylene wear in cemented metal-backed acetabular cups.
We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...
متن کاملTotal Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner
PURPOSE This retrospective study was performed to evaluate the clinical results and measure polyethylene liner wear in total hip arthroplasty (THA) with highly cross-linked polyethylene. MATERIALS AND METHODS Except for patients who had died or were unable to have follow-up at least 2 years, 60 of 78 hips that underwent THA were included this study. The mean age was 64.5 years (range, 25-81 y...
متن کاملPolyethylene wear in total hip arthroplasty.
Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined poly...
متن کاملUsing the transverse acetabular ligament as a landmark for acetabular anteversion: an intra-operative measurement.
PURPOSE. To measure the transverse acetabular ligament (TAL) anteversion in hips with severe deformity, using fluoroscopy-computed tomographic navigation. METHODS. 31 hips in 10 men and 19 women aged 40 to 78 (mean, 58.7) years who underwent total hip arthroplasty for primary osteoarthritis (n=6) or osteoarthritis secondary to developmental hip dysplasia (n=19) or congenital hip dislocation (n=...
متن کامل