In femtosecond laser-assisted cataract surgery, the parameter such as horizontal spot spacing and energy level can be adjusted. Although there have been several studies reported on various laser systems, showing the effects of varying energy levels and horizontal spot spacing on lens capsulotomy cut edges, none have been reported on the Catalys laser system (Abbott Medical Optics, Inc., Santa Ana, CA). The aim of this study is to evaluate, using scanning electron microscopy (SEM), the quality of the cut edges of the laser lens capsulotomy obtained using the Catalys Laser System, using different horizontal spot spacing and energy levels, and to determine the ideal parameters based on SEM results. Fifty rabbit capsulorhexis specimens from a femtosecond laser with different spot spacing and energy settings were divided into five groups randomly. Spot spacing was 3 um and laser pulse energy was 4 uJ in group 1. The respective values were 5 um and 2 uJ in group 2, 5 um and 4 uJ in group 3, 5 um and 6 uJ in group 4, and 7 um and 4 uJ in group 5. All samples were evaluated using SEM to compare the number of tags per capsulotomy and the laser emission time. Group 1 had a significantly lower tag formation than groups 3 and 5 (P = 0.042 and 0.021, respectively). Although the laser emission time increased about 1.5 sec as the spot spacing increased from 3 to 7 um, the quality of the cut was smoother in group 1 because of overlapping effect of photodisruption cavities. There was no significant difference between groups 2, 3 and 4 at different laser energy settings. In an ex-vivo study, samples from an energy setting of 10 uJ showed increased irregularity and damage. The degree of irregularity was higher at increasing spot spacing and laser energy settings, with abundant tag formation. Dense spot spacing with low-energy settings provide a better cut quality, which is probably correlated with the reduction in anterior capsular tear complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy

Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...

متن کامل

Cataract Surgery Performed by High Frequency LDV Z8 Femtosecond Laser: Safety, Efficacy, and Its Physical Properties

BACKGROUND The aim of our study was to investigate the safety and efficacy of the LDV Z8 femtosecond laser in cataract surgery compared to the conventional procedure. METHODS This prospective study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. The study included 130 eyes from 130 patients: 68 treated with femtosecond laser-assisted cataract surge...

متن کامل

Light microscopy and scanning electron microscopy analysis of rigid curved interface femtosecond laser-assisted and manual anterior capsulotomy.

PURPOSE To study the microanatomic edge structures of anterior lens capsule specimens derived from manual and femtosecond laser-assisted capsulotomies. SETTING Department of Ophthalmology, Goethe-University, Frankfurt, Germany. DESIGN Experimental study. METHODS Of 60 eyes with lens removal and intraocular lens implantation, 30 received a manual capsulotomy and 30 received a femtosecond l...

متن کامل

Femtosecond optical ranging of corneal incision depth.

Excimer laser ablation has been proposed as a technique for keratorefractive surgery. Clinical acceptance of linear-incision laser keratectomy may depend on the availability of a method for accurately and noninvasively monitoring incision depth during the ablation process. We have developed a femto-second optical ranging technique for measurement of corneal incision depth. This technique uses n...

متن کامل

Inverse Cutting of Posterior Lamellar Corneal Grafts by a Femtosecond Laser

PURPOSE Posterior lamellar grafting of the cornea has become the preferred technique for treatment of corneal endothelial dysfunction. Posterior lamellar grafts are usually cut by a micro-keratome or a femto-second laser after the epithelial side of the donor cornea has been applanated. This approach often results in variable central graft thickness in different grafts and an increase in graft ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018