Dependence of DCE-MRI biomarker values on analysis algorithm

نویسندگان

  • Chaan S. Ng
  • Wei Wei
  • James A. Bankson
  • Murali K. Ravoori
  • Lin Han
  • David W. Brammer
  • Sherry Klumpp
  • John C. Waterton
  • Edward F. Jackson
  • Zhuoli Zhang
چکیده

BACKGROUND Dynamic contrast-enhanced MRI (DCE-MRI) biomarkers have proven utility in tumors in evaluating microvascular perfusion and permeability, but it is unclear whether measurements made in different centers are comparable due to methodological differences. PURPOSE To evaluate how commonly utilized analytical methods for DCE-MRI biomarkers affect both the absolute parameter values and repeatability. MATERIALS AND METHODS DCE-MRI was performed on three consecutive days in twelve rats bearing C6 xenografts. Endothelial transfer constant (Ktrans), extracellular extravascular space volume fraction (ve), and contrast agent reflux rate constant (kep) measures were computed using: 2-parameter ("Tofts" or "standard Kety") vs. 3-parameter ("General Kinetic" or "extended Kety") compartmental models (including blood plasma volume fraction (vp) with 3-parameter models); individual- vs. population-based vascular input functions (VIFs); and pixel-by-pixel vs. whole tumor-ROI. Variability was evaluated by within-subject coefficient of variation (wCV) and variance components analyses. RESULTS DCE-MRI absolute parameter values and wCVs varied widely by analytical method. Absolute parameter values ranged, as follows, median Ktrans, 0.09-0.18 min-1; kep, 0.51-0.92 min-1; ve, 0.17-0.23; and vp, 0.02-0.04. wCVs also varied widely by analytical method, as follows: mean Ktrans, 32.9-61.9%; kep, 11.6-41.9%; ve, 16.1-54.9%; and vp, 53.9-77.2%. Ktrans and kep values were lower with 3- than 2-parameter modeling (p<0.0001); kep and vp were lower with pixel- than whole-ROI analyses (p<0.0006). wCVs were significantly smaller for ve, and larger for kep, with individual- than population-based VIFs. CONCLUSIONS DCE-MRI parameter values and repeatability can vary widely by analytical methodology. Absolute values of DCE-MRI biomarkers are unlikely to be comparable between different studies unless analyses are carefully standardized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Role of Quantitative Magnetic Resonance Imaging Parameters in the Evaluation of Treatment Response in Malignant Tumors

OBJECTIVE To elaborate the role of quantitative magnetic resonance imaging (MRI) parameters in the evaluation of treatment response in malignant tumors. DATA SOURCES Data cited in this review were obtained mainly from PubMed in English from 1999 to 2014, with keywords "dynamic contrast-enhanced (DCE)-MRI," "diffusion-weighted imaging (DWI)," "microcirculation," "apparent diffusion coefficient...

متن کامل

Automated localization of breast cancer in DCE-MRI

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is increasingly being used for the detection and diagnosis of breast cancer. Compared to mammography, DCE-MRI provides higher sensitivity, however its specificity is variable. Moreover, DCE-MRI data analysis is time consuming and depends on reader expertise. The aim of this work is to propose a novel automated breast cancer localiza...

متن کامل

Dynamic contrast-enhanced magnetic resonance imaging as an imaging biomarker.

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is being used in oncology as a noninvasive method for measuring properties of the tumor microvasculature. There is potential for DCE-MRI to be used as an imaging biomarker to measure antiangiogenic effects of cancer treatments. This article reviews the general methodology for performing DCE-MRI and discusses existing data and challe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015