False Positive Aortic Dissection on Abdominal Ultrasound
نویسندگان
چکیده
A 43-year-old man presented to the emergency department (ED) with epigastric pain radiating down the center of his abdomen. He denied significant use of alcohol or non-steroidal anti-inflammatory drugs. He had uncontrolled hypertension on hydrochlorothiazide and a blood pressure of 185/95 mmHg. A two-dimensional aortic ultrasound was done at the patient's bedside and revealed a double lumen and an intimal flap on the longitudinal axis (Figure 1). The transverse view was limited due to body habitus and bowel gas. Subsequent aortic computed tomography (CT) revealed an inflamed pancreatic head and a normal aorta (Figure 2). Lipase was elevated (1063 units/L). This patient's aorta appeared as a false positive abdominal aortic dissection on bedside ED ultrasound. Radiologists refer to this aorta as normal despite its curvature. There is a case report of a tortuous thoracic aorta that led to a false positive descending thoracic aortic dissection on transesophageal echocardiogram. 1 Severe tortuosity is usually seen in the thorax and may be associated with aortic aneurysms; however, this patient's curvature does not indicate pathology. The abnormal curvature in this patient's distal aorta allows for the impression on ultrasound that there is a false lumen and aneurysmal dilation. The retroaortic tissue appears to be a false lumen. There is also the appearance of an intimal flap and communication with the false lumen on ultrasound. These findings are likely due to artifact created by overlying bowel gas, which is present directly above that segment Figure 2. Computed tomography aorta sagittal reconstruction. Arrow indicates location of transducer in Figure 1.
منابع مشابه
Common iliac artery tortuosity simulating aortic dissection on focused abdominal ultrasound in the emergency department.
BACKGROUND Bedside ultrasonography performed by the Emergency Physician is a safe procedure for evaluating patients with trauma, hypotension, chest or abdominal pain, and dyspnea of unknown origin. OBJECTIVES To present a case with apparent concordance between the patient's history, symptoms, signs, and ultrasound imaging, that lead to diagnostic error. CASE REPORT A 74-year-old man was adm...
متن کاملFalse positive computed tomographic angiography for Stanford type A aortic dissection
BACKGROUND Computed tomographic angiography (CTA) has emerged as the defacto imaging test to rule out acute aortic dissection; however, it is not without flaws. We report a case of a false-positive CTA with respect to Stanford Type A aortic dissection. CASE A 52 year-old male presented with sudden onset shortness of breath. He denied chest pain. Due to severe hypertension and an Emergency Dep...
متن کاملEmergency bedside ultrasound diagnosis of superior mesenteric artery dissection complicating acute aortic dissection.
BACKGROUND A timely diagnosis of aortic dissection is associated with lower mortality. The use of emergent bedside ultrasound has been described to diagnose aortic dissection. However, there is limited literature regarding the use of bedside ultrasound to identify superior mesenteric artery dissection, a known high-risk feature of aortic dissection. OBJECTIVE Our aim was to present a case of ...
متن کاملChronic Abdominal Aortic Dissection with Large Aneurysm Unsuitable for Endovascular Treatment
A 70 year-old male sustained an AAD 8 years previously and was being monitored for an enlarging abdominal aortic aneurysm (AAA). A computed tomography (CT) scan confirmed an 8cm diameter AAA extending 9cm above the origin of the coeliac axis (CA). At the level of renal arteries (RAs) there was a dissection flap pressurising the false lumen. Both the RAs arose from the true lumen as did the supe...
متن کاملAortic Dissection and Thrombosis Diagnosed by Emergency Ultrasound in a Patient with Leg Pain and Paralysis
The authors present a case of aortic dissection and abdominal aortic aneurysm thrombosis in a 78-year-old male who presented to the emergency department (ED) complaining of lower extremity and paralysis for the past 1.5 hours. The initial vital signs in the ED were as follows: blood pressure (BP) 132/88 mmHg, heart rate (HR) 96, respiratory rate (RR) 14, and an oxygen saturation of 94% at room ...
متن کامل