Measurement of volatile organic compounds emitted in libraries and archives: an inferential indicator of paper decay?

نویسندگان

  • Lorraine T Gibson
  • Abdunaser Ewlad-Ahmed
  • Barry Knight
  • Velson Horie
  • Gemma Mitchell
  • Claire J Robertson
چکیده

BACKGROUND A sampling campaign of indoor air was conducted to assess the typical concentration of indoor air pollutants in 8 National Libraries and Archives across the U.K. and Ireland. At each site, two locations were chosen that contained various objects in the collection (paper, parchment, microfilm, photographic material etc.) and one location was chosen to act as a sampling reference location (placed in a corridor or entrance hallway). RESULTS Of the locations surveyed, no measurable levels of sulfur dioxide were detected and low formaldehyde vapour (< 18 μg m-3) was measured throughout. Acetic and formic acids were measured in all locations with, for the most part, higher acetic acid levels in areas with objects compared to reference locations. A large variety of volatile organic compounds (VOCs) was measured in all locations, in variable concentrations, however furfural was the only VOC to be identified consistently at higher concentration in locations with paper-based collections, compared to those locations without objects. To cross-reference the sampling data with VOCs emitted directly from books, further studies were conducted to assess emissions from paper using solid phase microextraction (SPME) fibres and a newly developed method of analysis; collection of VOCs onto a polydimethylsiloxane (PDMS) elastomer strip. CONCLUSIONS In this study acetic acid and furfural levels were consistently higher in concentration when measured in locations which contained paper-based items. It is therefore suggested that both acetic acid and furfural (possibly also trimethylbenzenes, ethyltoluene, decane and camphor) may be present in the indoor atmosphere as a result of cellulose degradation and together may act as an inferential non-invasive marker for the deterioration of paper. Direct VOC sampling was successfully achieved using SPME fibres and analytes found in the indoor air were also identified as emissive by-products from paper. Finally a new non-invasive, method of VOC collection using PDMS strips was shown to be an effective, economical and efficient way of examining VOC emissions directly from the pages of a book and confirmed that toluene, furfural, benzaldehyde, ethylhexanol, nonanal and decanal were the most concentrated VOCs emitted directly from paper measured in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Reactivity Based Emission Inventory for the South Pars and Its Implication for Ozone Pollution Control

The South Pars zone in Iran encompasses the largest gas refineries and petrochemical complexes in the world. In the South Pars zone, elevated concentrations of reactive hydrocarbons co-emitted with nitrogen oxides from industrial facilities lead to substantial ozone production downwind. To understand the role of these emissions on the ozone formation and, to formulate appropriate control st...

متن کامل

Source Apportionment Of High Reactive Volatile Organic Compounds In a Region With The Massive Hydrocarbon Processing Industries

In the Persian Gulf region, conditions are highly favorable for ozone air pollution and the region is a hot spot of photochemical smog. The vast activities in processing oil and gas play a major role in it. It was found that the elevated concentrations of reactive hydrocarbons co-emitted with nitrogen oxides from Hydrocarbon Processing facilities lead to substantial ozone production. South Pars...

متن کامل

Assessment and control of VOCs emitted from gas stations in Tehran, Iran

In this research, gasoline vapours including Benzene, Toluene, Xylene (BTX) and Total Volatile Organic Compounds (TVOCs) emitted from vent pipes of underground storage tanks (USTs) were measured at six gas stations in Tehran. Thereafter, gas station No. 29 was selected as a pilot station and equipped with a vapour control system. The vapours were measured during the summer of 2013 and winter of...

متن کامل

Assessment and control of VOCs emitted from gas stations in Tehran, Iran

In this research, gasoline vapours including Benzene, Toluene, Xylene (BTX) and Total Volatile Organic Compounds (TVOCs) emitted from vent pipes of underground storage tanks (USTs) were measured at six gas stations in Tehran. Thereafter, gas station No. 29 was selected as a pilot station and equipped with a vapour control system. The vapours were measured during the summer of 2013 and winter of...

متن کامل

The concentration of volatile organic compounds (VOCs) and related factors in the air in barbershops in Sanandaj in 2016

The aim of this study was to determine the density of benzene and toluene in barbershops of Sanandaj and also to determine effective factors for this pollution. A descriptive, analytical study was conducted to measure the volatile organic compound density and determine the effective factors. In this study, five hair salons and five barber shops were randomly selected from Sanandaj city. The vol...