Intraoperative electromyography monitoring in minimally invasive transforaminal lumbar interbody fusion.
نویسندگان
چکیده
OBJECT Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular method for achieving lumbar decompression and fusion. The procedure is technically more demanding than open fusion, with correspondingly more theoretical risk of complication. The authors describe the use of intraoperative electromyography (EMG) as an adjunct to surgery to reduce the risk of complications. METHODS Between August 2005 and April 2006, 25 consecutive patients underwent minimally invasive TLIF in which a total of 105 pedicle screws were placed. Intraoperative EMG was performed and included passive recordings during decompression and interbody graft placement, as well as active recording during the placement of the pedicle access needle and testing of the pedicle tap. A uniform protocol for active monitoring was used, with the pedicle access needle set at 7 mA. To assess hardware placement, all patients underwent postoperative radiography and 20 underwent postoperative computed tomography (CT) scanning. In no patient did the authors observe significant EMG activation during decompression. In five cases, intermittent nerve root firing was noted after the interbody graft was placed, but this did not correlate with any postoperative deficits. Using the active stimulation protocol, 76.2% of screw placements required one or more changes to the trajectory of the pedicle access needle. With successful placement of the pedicle access needle, in all 105 screws, the pedicle tap nerve root stimulation threshold was greater than 15 mA. Postoperative radiography was performed in all patients and CT scanning was performed in 20 patients (with 85 screws being placed). Postoperative imaging revealed only three cases of pedicle breach. In all cases, the breach was at the lateral wall of the pedicle and not thought to be clinically relevant. CONCLUSIONS A continuous stimulation pedicle access needle alerts the surgeon to incorrect medial trajectories and may lead to safer pedicle cannulation. As a result of electrophysiological feedback, the pedicle access needle trajectory was altered in 76.2% of the reported cases. The use of the authors' protocol resulted in a 0% incidence of clinically relevant malpositioned hardware and a low overall neurological complication rate. Intraoperative nerve root monitoring is a useful adjunct to minimally invasive TLIF.
منابع مشابه
MLIF - Minimally Invasive Lumbar Interbody Fusion MTLIF - Minimally Transforaminal Lumbar Interbody Fusion ODI - Oswestry Disability Index PLIF - Posterior Lumbar Interbody Fusion TLIF - Transforaminal Lumbar Interbody Fusion VAS - Visual Analog Scale
A prospective multicentral observational study of minimally invasive fusion to treat degenerative lumbar disorders, and to report outcomes of one or two level minimally invasive posterior lumbar interbody fusion (MLIF) for degenerative lumbar disorders in a multi-center 1-year prospective study. We prospectively studied a group of 32 patients, mostly female 24 (75% female), and 8 males (25%). T...
متن کاملEfficacy of minimally invasive transforaminal lumbar interbody fusion for single-segment lumbar degenerative disease
Lumbar degenerative disease is the major cause of low back pain. Currently, surgical treatment remains the standard care for lumbar degenerative disease. This study aimed to evaluate the efficacy and complications of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for the treatment of single-segment lumbar degenerative disease. A total of 75 patients with single-segment lum...
متن کاملRole of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review
Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...
متن کاملMinimally invasive transforaminal lumbar interbody fusion: indications, technique, and complications.
The authors provide an overview of the minimally invasive transforaminal lumbar interbody fusion (TLIF) procedure including indications, technique, and complications. This novel technique is a method of achieving circumferential lumbar fusion using a unilateral dorsal approach. Minimally invasive TLIF uses a tubular retractor that is inserted via a muscle-dilating exposure, thereby minimizing t...
متن کاملMinimally Invasive Transforaminal Lumbar Interbody Fusion: Technical Note
Minimally invasive techniques for lumbar interbody fusion have become increasingly popular recently. A limitation of these procedures is the restricted field of view, which requires a thorough understanding of the three-dimensional spinal landmarks and appropriate technical skills. We outline the operative steps used in said cases and provide illustrative video and figures.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurosurgery. Spine
دوره 6 2 شماره
صفحات -
تاریخ انتشار 2007