Weighted frequency-difference EIT measurement of hemisphere phantom
نویسندگان
چکیده
We have proposed a new frequency difference method using a weighted voltage difference (WFD-EIT) between two frequencies [1, 2]. Previous studies demonstrated its feasibility through numerical experiments and two-dimensional phantom experiments. In this study, we validate the WFD-EIT algorithm on a three-dimensional hemisphere phantom using a multi-frequency EIT system KHU Mark1. We built the hemisphere phantom with 17 stainless-steel electrodes on its inner surface. We filled the phantom with a biological material having a frequency-dependent admittivity such as carrot pieces mixed in saline. Using boundary voltage data from the deformed phantom, we reconstructed weighted frequency difference images on the computational model domain with a hemisphere shape. We discuss comparative reconstruction performance results including time difference (TD), simple frequency difference (FD), and weighted frequency difference (WFD). Animal and human head imaging experiments with the weighted frequency-difference EIT method are under investigation.
منابع مشابه
Calibration methods for a multi-channel multi-frequency EIT system.
Multi-channel multi-frequency electrical impedance tomography (EIT) systems require a careful calibration to minimize systematic errors. We describe novel calibration methods for the recently developed KHU Mark1 EIT system. Current source calibration includes maximization of output resistance and minimization of output capacitance using multiple generalized impedance converters. Phase and gain ...
متن کاملA phantom for assessing the performance of EIT systems
This paper describes a phantom built from 340 precision resistors on a printed circuit board (PCB) representing a circular homogeneous medium. Compared to other phantoms in the literature, this phantom generates very realistic signals while preserving the ability to produce localized perturbations for testing the imaging capabilities of an EIT system. Equivalent electrical models of the Ag/AgCl...
متن کاملMulti-frequency EIT system with radially symmetric architecture: KHU Mark1.
We describe the development of a multi-frequency electrical impedance tomography (EIT) system (KHU Mark1) with a single balanced current source and multiple voltmeters. It was primarily designed for imaging brain function with a flexible strategy for addressing electrodes and a frequency range from 10 Hz-500 kHz. The maximal number of voltmeters is 64, and all of them can simultaneously acquire...
متن کاملElectrical impedance tomography in 3D using two electrode planes: characterization and evaluation.
Electrical impedance tomography (EIT) uses body surface electrical stimulation and measurements to create conductivity images; it shows promise as a non-invasive technology to monitor the distribution of lung ventilation. Most applications of EIT have placed electrodes in a 2D ring around the thorax, and thus produced 2D cross-sectional images. These images are unable to distinguish out-of-plan...
متن کاملReal-time monitoring of tissue property in a liver phantom using an internal electrode and weighted frequency difference conductivity during microwave ablation
We measured the time difference and weighted frequency difference conductivity images to monitor the changes of temperature and tissue property in a liver phantom due to the microwave ablation. Pixels in regions of interest were compared between conventional boundary surface electrode method and focused configuration with an internal electrode.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010