In order to solve the problems caused by the susceptibility to changing weather conditions and the complex load conditions of photovoltaic (PV) systems, and the fact a single target inverter control strategy cannot effectively mitigate large voltage fluctuations at point of common coupling (PCC), an integrated reactive power control strategy for PV inverters is proposed. According to the weather and load conditions, this strategy is divided into four control modes: normal operation control mode, reverse power control mode, cloudy control mode and night control mode. The four control modes switch between each other under the specific switching rules to ensure an appropriate quantity of reactive power injection or consumption in the PV inverter. The effects of the four control modes in isolated operation were significant. The deviation rate of PCC voltage from its standard value was mitigated at about 2% under the integrated control strategy. Therefore, the proposed control strategy has a high application value in improving power quality and maximizing utilization of PV inverters.
منابع مشابه
A Grid-Connected PV Inverter with Compensation of Load Active and Reactive Power Imbalance for Distribution Networks
Load balancing is an important issue in distributed systems. In addition, using distributed generation sources such as photovoltaic is increasing. Power electronic converters are main interfaces between the sources and the grid. In this paper, a method has been proposed to reduce the load imbalancing in distribution networks using PV Grid Interface Converter. Two DC/DC and DC/AC converters have...
متن کاملDesign of A Single-Phase Transformerless Grid-Connected PV Inverter Considering Reduced Leakage Current and LVRT Grid Codes
A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...
متن کاملDesign and Implementation of the Predictive Current Control Strategy in the Single Phase Photovoltaic Grid-Connected Inverter Based on Microcontroller
In this paper, photovoltaic (PV) grid-connected inverter which is the core device in PV grid-connected system has been in depth research.An improved predictive current controller has been developed by the Authors for single-phase grid-connected voltage source inverters (VSI).Based on DSP TMS320LF2407A, a 10 kW single-phase grid-connected inverter has been built in this paper.Thus is aimed at us...
متن کاملA Grid Connected Transformerless Inverter and its Model Predictive Control Strategy with Leakage Current Elimination Capability
This paper proposes a new single phase transformerless Photovoltaic (PV) inverter for grid connected systems. It consists of six power switches, two diodes, one capacitor and filter at the output stage. The neutral of the grid is directly connected to the negative terminal of the source. This results in constant common mode voltage and zero leakage current. Model Predictive Controller (MPC) tec...
متن کاملNew Strategy of Grid Connected Photovoltaic System Using Module Integrated Converters with B4 Inverter to Overcome Partial Shading Effect
This paper proposes a new configuration for solar energy conversion systems. One challenging issue of the photovoltaic (PV) systems is partial shading, and in this paper Module Integrated Converters (MIC) are used to overcome this problem in PV arrays. A few boost converters are employed as MICs to mitigate the shading effect. Furthermore, to reduce the cost and to increase the system performan...