3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction.

نویسندگان

  • Y Wu
  • N Kim
  • F R Korosec
  • A Turk
  • H A Rowley
  • O Wieben
  • C A Mistretta
  • P A Turski
چکیده

HYPR TRICKS is an acquisition method that combines radial k-space trajectories, sampling k-space at different rates (TRICKS), and a new strategy for image reconstruction that uses highly constrained backprojection reconstruction (HYPR). This approach provides 3D time-resolved contrast-enhanced MR angiograms of the cerebral vessels with subsecond frame update times and submillimeter in-plane spatial resolution. Artifacts are suppressed, and signal-to-noise ratio is well maintained, by using HYPR reconstruction.

منابع مشابه

Time-resolved angiography: Past, present, and future.

The introduction of digital subtraction angiography (DSA) in 1980 provided a method for real time 2D subtraction imaging. Later, 4D magnetic resonance (MR) angiography emerged beginning with techniques like Keyhole and time-resolved imaging of contrast kinetics (TRICKS) that provided frame rates of one every 5 seconds with limited spatial resolution. Undersampled radial acquisition was subseque...

متن کامل

Accelerated 3D Time-Resolved MR Angiography using Cartesian HYPR LR Reconstruction

INTRODUCTION In many MR applications, it is desirable to achieve high spatial and temporal resolution at the same time, such as contrast-enhanced MR angiography (CE-MRA). However, fully-sampled Cartesian acquisition for large matrices is extremely time consuming and precludes the simultaneous achievement of both goals. Several Cartesian undersampling methods, such as CAPR [1], TRIPPS [2] and va...

متن کامل

Accelerated Time Resolved Inflow with 3D Multi-Echo Radial Trajectories

Introduction: Arterial spin labeling (ASL) sequences which utilize tagging schemes to images the flow of blood have emerged as effective techniques for the non-contrast angiography; however, these techniques typically suffer from long acquisition times, sensitivity to tag delay parameters, and uncertain performance in cases of complex flow [1-3]. To mitigate these errors, we have previously dem...

متن کامل

Fast whole-brain 4D contrast-enhanced MR angiography with velocity encoding using undersampled radial acquisition and highly constrained projection reconstruction: image-quality assessment in volunteer subjects.

We report on the image quality obtained by using fast contrast-enhanced whole-brain 4D radial MRA with 0.75-second temporal resolution, isotropic submillimeter spatial resolution, and velocity encoding (HYPRFlow). Images generated by HYPR-LR by using the velocity-encoded data as the constraining image were of diagnostic quality. In addition, we demonstrate that measurements of shear stress with...

متن کامل

Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The pu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 10  شماره 

صفحات  -

تاریخ انتشار 2007