Variations in the Potency of Digitalis Preparations in the Tropics (II)
نویسندگان
چکیده
منابع مشابه
شناسایی گلیکوزیدهای قلبی گونه دیژیتال ایران به روش HPLC
Background and Purpose: Digitalis species and their cardiac glycosides are used in congestive heart failure (ÇHF) disease. Digitalis nervosa are grown only in the North regions of Ïran. Çardiac glycosides of other species are identified by HPLÇ procedure. Ïn this research, cardiac glycosides of Digitalis nervosa were identified. Materials and Methods: Ïn this research, methanol as solvent ...
متن کاملA New Method to Estimate Inhibition Percentage of Endogenous Digitalis in Patients with Pre-eclampsia
Background: Pre-eclampsia is an idiopathic pregnancy disorder characterized by appearance proteinuria and hypertension, with poorly understood etiology. It has been linked to a variety of system abnormalities, including ion transport disorders in neonatal, maternal, and placental cell lines. A new method was described to evaluate the inhibition percentage of endogenous digitalis in plasma of pr...
متن کاملQuantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملZinc, boron and sulphur deficiencies are holding back the potential of rainfed crops in semi-arid India: Experiences from participatory watershed management
Little attention has been paid to the diagnosis of deficiencies of micronutrients such as zinc (Zn) and boron (B) and secondary nutrient such as sulphur (S) in rainfed systems. We evaluated Zn, B and S status of 1617 farmers’ fields in 14 districts of the semi-arid tropical India. Results showed that most of the soil samples were low to medium in organic carbon contents. Results also revealed t...
متن کاملSoluble Leishmanin as an Ideal Reagent for Skin Testing in Human Leishmaniasis
Delayed-type hypersensitivity reaction measured by skin testing, is an important tool for evaluation of cellular immune response in leishmaniasis and has been used recently as an indication of exposure to infection. Skin testing in leishmania infection needs a standard reagent with high specificity, sensitivity, and potency. In the present work, a soluble leishmanin, and three whole parasite p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 61 شماره
صفحات -
تاریخ انتشار 2017