Protective coatings for intraocular wirelessly controlled microrobots for implantation: Corrosion, cell culture, and in vivo animal tests.

نویسندگان

  • Juho Pokki
  • Olgaç Ergeneman
  • George Chatzipirpiridis
  • Tessa Lühmann
  • Jordi Sort
  • Eva Pellicer
  • Simon A Pot
  • Bernhard M Spiess
  • Salvador Pané
  • Bradley J Nelson
چکیده

Diseases in the ocular posterior segment are a leading cause of blindness. The surgical skills required to treat them are at the limits of human manipulation ability, and involve the risk of permanent retinal damage. Instrument tethering and design limit accessibility within the eye. Wireless microrobots suturelessly injected into the posterior segment, steered using magnetic manipulation are proposed for procedures involving implantation. Biocompatibility is a prerequisite for these procedures. This article investigates the use of polypyrrole- and gold-coated cobalt-nickel microrobots. While gold has been used in ocular implants, no ocular implantation involving polypyrrole is reported, despite its well-established biocompatibility properties. Coated and uncoated microrobots were investigated for their corrosion properties, and solutions that had contained coated and uncoated microrobots for one week were tested for cytotoxicity by monitoring NIH3T3 cell viability. None of the microrobots showed significant corrosion currents and corrosion potentials were as expected in relation to the intrinsic nobility of the materials. NIH3T3 cell viability was not affected by the release medium, in which coated/uncoated microrobots were stored. In vivo tests inside rabbit eyes were performed using coated microrobots. There were no significant inflammatory responses during the first week after injection. An inflammatory response detected after 2 weeks was likely due to a lack of longer-duration biocompatibility. The results provide valuable information for those who work on implant technology and biocompatibility. Coated microrobots have the potential to facilitate a new generation of surgical treatments, diagnostics and drug-delivery techniques, when implantation in the ocular posterior segment will be possible. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 836-845, 2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corrosion Tests of Steel Earthing Electrodes with Protective Coatings Made from Different Materials

In the paper the methodology and test results of field and laboratory corrosion tests of steel earthing rods with zinc galvanized coatings and copperbonded coatings are described. The corrosion rate and level of corrosion damage of earthing rods with two different protective coatings have been compared as well some conclusions related to reliability and assessment of technical “life time” of st...

متن کامل

رسوب‌دهی الکتریکی پوشش نیکل- مولیبدن بر فولاد زنگ‌نزن جهت استفاده به‌عنوان صفحات دوقطبی پیل سوختی پلیمری

Stainless steel bipolar plates are preferred choice for use in Proton Exchange Membrane Fuel Cells (PEMFCs). However, regarding the working temperature of 80 °C and corrosive and acidic environment of PEMFC, it is necessary to apply conductive protective coatings resistant to corrosion on metallic bipolar plate surfaces to enhance its chemical stability and performance. In the present study...

متن کامل

In vitro versus In vivo: Development-, Apoptosis-, and Implantation-Related Gene Expression in Mouse Blastocyst

Background: While mammalian embryos can adapt to their environments, their sensitivity overshadows their adaptability in suboptimal in vitro conditions. Therefore, the environment in which the gametes are fertilized or to which the embryo is exposed can greatly affect the quality of the embryo and consequently its implantation potential. Objectives:</stro...

متن کامل

I-5: Molcular and Cellular Interactions in UterineReceptivity for Implantation

Background: Though plausible candidate adhesion systems have been identified, current knowledge of embryo-maternal attachment in human is limited by the inability to conduct well-controlled functional investigations. We have sought a viable medium-throughput model for the identification and functional assessment of molecular markers in the initial epithelial phases of implantation. An ideal mod...

متن کامل

Mobility experiments with microrobots for minimally invasive intraocular surgery.

PURPOSE To investigate microrobots as an assistive tool for minimally invasive intraocular surgery and to demonstrate mobility and controllability inside the living rabbit eye. METHODS A system for wireless magnetic control of untethered microrobots was developed. Mobility and controllability of a microrobot are examined in different media, specifically vitreous, balanced salt solution (BSS),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical materials research. Part B, Applied biomaterials

دوره 105 4  شماره 

صفحات  -

تاریخ انتشار 2017