Development of a micro cell compression stimulator for evaluating real-time cellular responses.

نویسندگان

  • Y Nakashima
  • Y Yang
  • K Minami
چکیده

This paper presents a micro cell compression stimulator for evaluating real-time cellular responses to compression stimuli. The device was produced by a micro three-dimensional structure fabrication process using multiple exposures to the photoresist. The device consists of a pressure inlet port, cell inlet ports, a gasket, microchannels, cell culture chambers, and a diaphragm on the culture chamber for applying compressive pressure to cells. Compression stimuli applied to the cells can be controlled by regulating the expansion of the diaphragm via a pressure control. The device permits the observation of cellular responses to compressive pressure in real time because it is made of transparent materials and stimulates the cells without deforming the cell culture surface, when observed by optical microscopy. We demonstrated the validity of the fabrication process, evaluated the performance of the fabricated device, and compared the experimental results with the FEM structural analysis results. We found through operational testing that the diaphragm was deformed quickly by applying negative/positive pressure and that the diaphragm displacement became larger with increasing applied pressure. These results indicate that this device can be used to control the intensity and the cell stimulus profile by regulating the applied pressure. In all cases, the cellular deformation during compression stimulus was successfully observed in real time using an optical microscope. The device is expected to facilitate the control of stem cell differentiation and the clarification of cellular mechanoreceptor mechanisms and signal transduction pathways.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling of Compression Curves of Flexible Polyurethane Foam with Variable Density, Chemical Formulations and Strain Rates

Flexible Polyurethane (PU) foam samples with different densities and chemical formulations were tested in quasi-static stress-strain compression tests. The compression tests were performed using the Lloyd LR5K Plus instrument at fixed compression strain rate of 0.033 s-1 and samples were compressed up to 70% compression strains. All foam samples were tested in the foam rise direction and their ...

متن کامل

Characterization of Immune Responses Induced by Combined Clade-A HIV-1 Recombinant Adenovectors in Mice

Background: Numerous evidences indicate that in some HIV-1 positive patients, the humoral and cellular immune responses are induced against HIV-1 proteins and this is inversely related to the progress of infection. Objective: The aim of this study was the evaluation of the Adenovectors containing HIV genes in induction of immune responses in mice. Methods: The HIV-1 genes including gag p24, rev...

متن کامل

Effect of Fe additive on plastic deformation for crush-boxes with closed-cell metal foams, Part I: Al-composite foam compression response

AbstractIn this paper, we investigate effect of Fe–intermetallic compounds on plastic deformation of closed-cell composite Aluminum Foam as filler of thin-walled tubes. However, deformation of the Aluminum foam-filled thin-walled tubes as crushed-box will be presented in Part (II). Composite foams of AlSi7SiC3 and AlSi7SiC3-(Fe) as closed cell were synthesized by powder metallurgy foaming metho...

متن کامل

The Effect of Fe Additive on Plastic Deformation for Crush-Boxes with Closed-Cell Metal Foams, Part II: Al-Composite Foam-Filled brass tubes Compression Response

The brass tubes with foam cores of AlSi7SiC3, AlSi7SiC3Fe1 and AlSi7SiC3Fe3 were produced as the crush-boxes with circle and square cross-section. Then axial compressive behavior and energy absorption capability of the foam-filled tubes were investigated during the quasi-static progressive plastic buckling. The uniaxial compressive stress–strain curves of the foam-filled brass tubes exhibited t...

متن کامل

Evaluating the effect of pH on mechanical strength and cell compatibility of nanostructured collagen hydrogel by the plastic compression method

Objective(s): One of the main constraints of collagen hydrogel scaffolds for using in tissue engineering is mechanical weakness. Plastic compression (PC) is a physical method to overcome the mechanical limitation of collagen hydrogel. Materials and Methods: In this study, the effects of pH on mechanical and biological properties of PC hydrogels were investigated. Collagen hydrogels were fabrica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 2012