X-ray absorption tomography employing a conical shell beam.
نویسندگان
چکیده
We demonstrate depth-resolved absorption imaging by scanning an object through a conical shell of X-rays. We measure ring shaped projections and apply tomosynthesis to extract optical sections at different axial focal plane positions. Three-dimensional objects have been imaged to validate our theoretical treatment. The novel principle of our method is scalable with respect to both scan size and X-ray energy. A driver for this work is to complement previously reported methods concerning the measurement of diffracted X-rays for structural analysis. The prospect of employing conical shell beams to combine both absorption and diffraction modalities would provide enhanced analytical utility and has many potential applications in security screening, process control and diagnostic imaging.
منابع مشابه
An accuracy assessment of forensic computerized facial reconstruction employing cone-beam computed tomography from live subjects.
The utilization of 3D computerized systems has allowed more effective procedures for forensic facial reconstruction. Three 3D computerized facial reconstructions were produced using skull models from live adult Korean subjects to assess facial morphology prediction accuracy. The 3D skeletal and facial data were recorded from the subjects in an upright position using a cone-beam CT scanner. Shel...
متن کاملSelective deposition of Pt onto supported metal clusters for fuel cell electrocatalysts.
We report a new method for deposition of Pt on a metal core to develop real electrocatalysts with significantly reduced amounts of expensive Pt as well as enhanced activity for oxygen reduction reaction. Ru and Pd have different crystal structures and modify the electronic structure of Pt to a different extent (shifts in d-band center). They were chosen as core materials to examine whether hydr...
متن کاملEnergy-dispersive X-ray diffraction using an annular beam.
We demonstrate material phase identification by measuring polychromatic diffraction spots from samples at least 20 mm in diameter and up to 10 mm thick with an energy resolving point detector. Within our method an annular X-ray beam in the form of a conical shell is incident with its symmetry axis normal to an extended polycrystalline sample. The detector is configured to receive diffracted flu...
متن کاملAttenuation Correction of L-shell X-ray Fluorescence Computed Tomography Imaging
X-ray fluorescence computed tomography (XFCT) is an experimental technique that can reconstruct the distribution of elements within the sample from the measurement of fluorescence stimulated from the sample[1]. The sample is irradiated with a x-ray beam, of which the energy is greater than the K-shell energy or L-shell energy of the interest elements. These x rays undergo photoelectric interact...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 24 25 شماره
صفحات -
تاریخ انتشار 2016