Backscattering particle immunoassays in wire-guide droplet manipulations

نویسندگان

  • Jeong-Yeol Yoon
  • David J You
چکیده

A simpler way for manipulating droplets on a flat surface was demonstrated, eliminating the complications in the existing methods of open-surface digital microfluidics. Programmed and motorized movements of 10 muL droplets were demonstrated using stepper motors and microcontrollers, including merging, complicated movement along the programmed path, and rapid mixing. Latex immunoagglutination assays for mouse immunoglobulin G, bovine viral diarrhea virus and Escherichia coli were demonstrated by merging two droplets on a superhydrophobic surface (contact angle = 155 +/- 2 degrees ) and using subsequent back light scattering detection, with detection limits of 50 pg mL-1, 2.5 TCID50 mL-1 and 85 CFU mL-1, respectively, all significantly lower than the other immunoassay demonstrations in conventional microfluidics (~1 ng mL-1 for proteins, ~100 TCID50 mL-1 for viruses and ~100 CFU mL-1 for bacteria). Advantages of this system over conventional microfluidics or microwell plate assays include: (1) minimized biofouling and repeated use (>100 times) of a platform; (2) possibility of nanoliter droplet manipulation; (3) reprogrammability with a computer or a game pad interface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Open-Surface Digital Microfluidics

Open-surface digital microfluidics refers to droplet manipulations in an open surface. Different chemical/biological reaction protocols can easily be demonstrated in the same device by reprogramming the order of droplet manipulations. While continuous-flow or liquid-plug microfluidics within microchannels have inherently limited programmability, there is no limit of reprogrammability in open-su...

متن کامل

Droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling for simpler and faster PCR assay using wire-guided manipulations

A computer numerical control (CNC) apparatus was used to perform droplet centrifugation, droplet DNA extraction, and rapid droplet thermocycling on a single superhydrophobic surface and a multi-chambered PCB heater. Droplets were manipulated using "wire-guided" method (a pipette tip was used in this study). This methodology can be easily adapted to existing commercial robotic pipetting system, ...

متن کامل

Digital microfluidic magnetic separation for particle-based immunoassays.

We introduce a new format for particle-based immunoassays relying on digital microfluidics (DMF) and magnetic forces to separate and resuspend antibody-coated paramagnetic particles. In DMF, fluids are electrostatically controlled as discrete droplets (picoliters to microliters) on an array of insulated electrodes. By applying appropriate sequences of potentials to these electrodes, multiple dr...

متن کامل

Evaluation of guide wire cannulation in reduced risk of post - ERCP pancreatitis and facilitated bile duct cannulation

Background: Pancreatitis is most common complication of post-ERCP and needs to admission at least for one day. The purpose of this study was to assess the efficacy of guide wire for better common bile duct (CBD) cannulation for reducing post-ERCP pancreatitis. Methods: From April 2010 through March 2011, the patients who needed ERCP and referred to Shahid Beheshti and Rouhani Teaching Hospita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Biological Engineering

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008