Enhancement of solute removal in a hollow-fiber hemodialyzer by mechanical vibration.

نویسندگان

  • Jeong Chul Kim
  • Francesco Garzotto
  • Dinna N Cruz
  • Ching Yan Goh
  • Federico Nalesso
  • Ji Hyun Kim
  • Eungtaek Kang
  • Hee Chan Kim
  • Claudio Ronco
چکیده

Better solute clearance, particularly of middle-molecular-weight solutes, has been associated with improved patient outcomes. However, blood-membrane interaction during dialysis results in the development of secondary mass transfer resistances on the dialyzer membrane surface. We discuss the potential effects of mechanical vibration on the diffusion, convection and adsorption of uremic solutes during dialysis. For sinusoidal and triangular vibratory motions, we conceptualized the hemodynamic changes inside the membrane and consequent effects on membrane morphology. Longitudinal vibration generates reverse flow by relative membrane motion, and transverse vibration generates a symmetric swirling flow inside the hollow fiber, which enhances wall shear stress and flow mixing. Moreover, the impulse induced by triangle wave vibration could provide higher absorption capacity to middle-molecular-weight solutes. Mechanical vibration could enhance solute removal by minimizing membrane morphology changes resulting from blood-membrane interaction during hemodialysis. These effects of mechanical vibration can be helpful in extracorporeal blood purification therapies including continuous, portable and wearable systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and Simulation of CO2 Absorption Enhancement in Hollow-Fiber Membrane Contactors using CNT–Water-Based Nanofluids

Absorption of CO2 from a gas mixture containing CO2 and nitrogen by water-based CNT nanofluids in gas–liquid hollow fiber membrane contactor was modeled and solved using COMSOL Multiphysics 5.4. The model assumed partial wetting of the membrane, along with diffusion in the axial and radial directions. In addition, Brownian motion and grazing effects were both considered in the model. The main c...

متن کامل

Mathematical Modeling of Carbon Dioxide Removal from the CO2/CH4 Gas Mixture Using Amines and Blend of Amines in Polypropylene: A Comparison between Hollow Fiber Membrane Contactor and Other Membranes

In this work, a mathematical model is established to describe the removal of CO2 from gaseous mixtures including CH4 and CO2 in a polypropylene hollow fiber membrane contactor in the presence of conventional absorbents such as monoethanolamine (MEA), methyldiethanolamine (MDEA), and a blend of them. Modeling was performed in axial and radial directions under the fully-wet condition for counterc...

متن کامل

Hollow Fiber Membrane Bioreactor for COD Biodegradation of Tapioca Wastewater

The present work studied the application of membrane bioreactor (MBR) for tapioca wastewater processing that contained chemical oxygen demand (COD) ranging from 4000-9000 mg/L. A preliminary study was initially conducted in order to evaluate membrane performance with respect to its flux with MLSS concentration ranging from 4,500 to 10,500 mg/L. It was clear that fouling was observed during the ...

متن کامل

Negatively charged polyethersulfone hollow fiber nanofiltration membrane for the removal of bisphenol A from wastewater

Removal of endocrine disrupting compound (viz., bisphenol A, BPA) by laboratoryfabricated hollow fiber polyethersulfone (PES) nanofiltration (NF) membranes have been investigated. The tailor made charged PES hollow fiber NF membranes have been developed by blending negatively charged surface modifying macromolecule (cSMM). It is resulted more than 90% removal of BPA, mainly due to negatively ch...

متن کامل

Mathematical Modeling and Numerical Simulation of CO2 Removal by Using Hollow Fiber Membrane Contactors

Abstract In this study, a mathematical model is proposed for CO2 separation from N2/CO2 mixtureusing a hollow fiber membrane contactor by various absorbents. The contactor assumed as non-wetted membrane; radial and axial diffusions were also considered in the model development. The governing equations of the model are solved via the finite...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood purification

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2011