A novel high-throughput method for molecular serotyping and serotype-specific quantification of Streptococcus pneumoniae using a nanofluidic real-time PCR system.

نویسندگان

  • Bhim Gopal Dhoubhadel
  • Michio Yasunami
  • Lay-Myint Yoshida
  • Hien Anh Nguyen Thi
  • Thu Huong Vu Thi
  • Thuy Ai Nguyen Thi
  • Kiwao Watanabe
  • Motoi Suzuki
  • Konosuke Morimoto
  • Duc Anh Dang
  • Koya Ariyoshi
چکیده

Serotype-specific quantification data are essential for elucidating the complex epidemiology of Streptococcus pneumoniae and evaluating pneumococcal vaccine efficacy. Various PCR-based assays have been developed to circumvent the drawback of labour-intensive and time-consuming culture-based procedures for serotype determination and quantification of pneumococcus. Here, we applied a nanofluidic real-time PCR system to establish a novel assay. Twenty-nine primer pairs, 13 of which were newly designed, were selected for the assay to cover 50 serotypes including all currently available conjugate and polysaccharide vaccine serotypes. All primer pairs were evaluated for their sensitivity, specificity, efficiency, repeatability, accuracy and reproducibility on the Fluidigm Biomark HD System, a nanofluidic real-time PCR system, by drawing standard curves with a serial dilution of purified DNA. We applied the assay to 52 nasopharyngeal swab samples from patients with pneumonia confirmed by chest X-ray to validate its accuracy. Minimum detection levels of this novel assay using the nanofluidic real-time PCR system were comparable to the conventional PCR-based assays (between 30 and 300 copies per reaction). They were specific to their targets with good repeatability (sd of copy number of 0.1), accuracy (within ±0.1 fold difference in log10 copy number) and reproducibility (sd of copy number of 0.1). When artificially mixed DNA samples consisting of multiple serotypes in various ratios were tested, all the serotypes were detected proportionally, including a minor serotype of one in 1000 copies. In the nasopharyngeal samples, the PCR system detected all the culture-positive samples and 22 out of 23 serotypes identified by the conventional method were matched with PCR results. We conclude that this novel assay, which is able to differentially quantify 29 pneumococcus groups for 45 test samples in a single run, is applicable to the large-scale epidemiological study of pneumococcus. We believe that this assay will facilitate our understanding of the roles of serotype-specific bacterial loads and implications of multiple serotype detections in pneumococcal diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Streptococcus pneumoniae real-time PCR serotyping from pediatric parapneumonic effusions

BACKGROUND To determine the serotypes of Streptococcus pneumoniae responsible for pneumonia complicated by parapneumonic effusion in children, we performed real-time PCR based pneumococcal "serotyping" directly on parapneumonic fluid samples. METHODS Specimens were collected at two children's hospitals in Ontario, Canada from 2009 to 2011. Samples in which S. pneumoniae was detected by PCR we...

متن کامل

Molecular Detection and Serotyping of Streptococcus Pneumoniae in Children with Suspected Meningitis in Northeast Iran

Background: To date, more than 90 Streptococcus pneumoniae (S. pneumoniae) capsular serotypes are known. The prevalence of these serotypes varies according to the geographical area and the regional vaccination program. Due to the lack of regular vaccination programs for S. pneumoniae in developing countries, serotyping of the prevalent isolates is useful in selecting the correct vaccine. The pr...

متن کامل

A new serotyping method of S. pneumoniae using an automated microarray-based assay

Introduction / objectives Serotype replacement is a major concern following the introduction of polysaccharide-conjugated vaccine against S. pneumoniae and requires a close monitoring in the population. Antibody-based serotyping methods are expensive, semi quantitative, cross-reactions are common and a significant number of isolates cannot be typed. Multiplex PCR-based assays have been develope...

متن کامل

Assessing the diagnostic accuracy of PCR-based detection of Streptococcus pneumoniae from nasopharyngeal swabs collected for viral studies in Canadian adults hospitalised with community-acquired pneumonia: a Serious Outcomes Surveillance (SOS) Network of the Canadian Immunization Research (CIRN) study

STUDY DESIGN Detection and serotyping of Streptococcus pneumoniae are important to assess the impact of pneumococcal vaccines. This study describes the diagnostic accuracy of PCR-based detection of S. pneumoniae directly from nasopharyngeal (NP) swabs collected for respiratory virus studies. METHODS Active surveillance for community-acquired pneumonia (CAP) in hospitalised adults was performe...

متن کامل

Sequential multiplex PCR assay for determining capsular serotypes of colonizing S. pneumoniae

BACKGROUND Asymptomatic nasopharyngeal carriage represents an important biological marker for monitoring pneumococcal serotype distribution and evaluating vaccine effects. Serotype determination by conventional method (Quellung reaction) is technically and financially challenging. On the contrary, PCR-based serotyping represents a simple, economic and promising alternative method. METHOD We d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical microbiology

دوره 63 Pt 4  شماره 

صفحات  -

تاریخ انتشار 2014